Original source · versioned page text
Reference Document - Bushfire Management Plan - 132005.638.04
Plans and drawings: the text below has words only, no drawings.
Very large file (28.2 MB): may take a few minutes to open.
30
Performance outcomes Acceptable outcomes Response
storing in bulk. stored in the bushfire hazard area
Access and Evacuation Routes
PO6 AO6.1 R6.1
Roads provide for easy and safe evacuation of The road layout provides for through-roads and
The Waste Management Centre has internal
residents of premises and access by avoids cul-de-sacs and dead-end roads.
private roadways and a single access point
emergency services.
onto a public roadway.
OR
However, the centre is separated from all
areas of hazardous vegetation by sufficient
AO6.2
firebreak and fire management lines.
The development has a perimeter road reserve
with a minimum width of 20 metres and
maximum gradient of 12.5%.
OR
AO6.3
Cul-de-sacs or no-through roads are provided with
fire trails or access easements, which are capable
of being navigated by conventional vehicles and
which link to through roads.
AO6.4
Safe access and egress is available at all times to
all of the development for emergency vehicles
and personnel.
AO6.5
Where an emergency access point is required, it
RFA24-059 – Noosa Land Fill and Waste Management Facility – Bushfire Management Plan
Rob Friend & Associates Pty Ltd 10th of October 2024
Document Set ID: 23617065
Version: 1, Version Date: 05/03/2025