Original source · versioned page text
Development Assessment Report
Specific Outcomes Probable solutions Proposal
O12 For Multiple housing Type 3 or 4, Not Applicable
Visitor accommodation Type 4, or the
accommodation unit component of an
Entertainment and dining
business Type 3—maximum gross floor
area is equivalent to the maximum
allowable population in persons
multiplied by 40m2.
O13 For the Business Centre Zone plot Not Applicable
ratio does not exceed—
a) 0.8:1 for site areas up to and including
2,000m2; and
b) 0.3:1 for the balance of a site over
2,000m2.
Flooding and drainage S14.1 For new buildings or structures or Not Applicable
O14 Buildings and other works are additions of more than 50m2 gross floor The site is not subject to flooding.
designed and sited to— area to an existing building or structure,
a) provide flood free access to premises floor levels for habitable rooms are—
and flood free habitable areas; a) for areas where minimum floor levels
b) allow only minor, short term and are available—not less than the specified
infrequent flooding of non-habitable level;
areas; b) for areas where flood modelling is
c) ensure carparking areas can be available—a minimum of 500mm above
adequately drained; the modelled flood level; and
d) ensure drainage does not adversely c) for areas where flood modelling is not
impact upon other premises; and available, a minimum of 500mm above
e) ensure filling or excavation does not the highest known flood level;
adversely impact upon other premises AND
by—
i. causing ponding of water on the S14.2 Where Council infrastructure is Complies
site or nearby land; available— The development will be drained to
ii. increasing flooding, which a) any drainage (including buildings and Council infrastructure. Refer attached
adversely affects the safety or use of yards) flows to that infrastructure; and Stormwater Management Plan prepared
any land upstream and downstream; b) the infrastructure has the capacity to by Empire Engineering.
and accept any additional loading;
iii. adversely affecting the flow of AND
water in any overland flow path.
S14.3 Car parking and manoeuvring Complies
areas are constructed at a level that No mechanical pumping drainage is
permits the parking area to drain from proposed or required.
the site by gravity means, without the
need for mechanical pumping; or
S14.4 Basements for residential uses Not Applicable
have flood immunity above the Q100
where alternative means to mechanical
pumping are used to achieve such
immunity; or
S14.5 Basements for non-residential Not Applicable
uses have flood immunity above the The site is not subject to flooding.
Q100 that may be achieved by means of
mechanical pumping where the
mechanical feature is installed with
adequate holding tanks and an
alternative back up power source.
Sloping sites S15.1 Buildings are of split level design Not Applicable
O15 On sloping sites, buildings and that step down the slope or have a The site is not a sloping site.
structures are designed to maximise the suspended floor construction; (See
use of natural slope and minimise the Figure 6.1 below)
need for cut and fill. AND
S15.2 Cut or fill is less than 2m in depth;
AND
S15.3 The distance between the ground
and the lowest part of the floor of the
building does not exceed 3m.
Figure 6.1—Design for sloping site
(suspended floor)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (Development Assessment Report.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.