Original source · versioned page text
8. Appendix E - Previous Approval
Very large file (11.2 MB): the original may take a few minutes to open or download. The page text below is quick to read.
(c) works programme identifying key components of the works and their respective durations (d) establishment of a communication protocol with the general public, adjoining owners, emergency services and local businesses to advise of agreed construction times, impacts on traffic and services and other relevant issues (e) identification of complaint management procedures including: (i) contact details for the on-site manager (ii) dispute resolution procedures (f) details on the location of external fill sites/sources, the haulage route, type of vehicle to be utilised during filling operations and frequency of usage. NB any damage to the existing road system as a result of haulage operations shall be fully repaired at the applicant’s expense (g) it is acknowledged that the Construction Management Plan will be a draft document requiring finalisation upon appointment of the Principal Contractor employed to construct the works and a final document will be required to be submitted at the Pre-Start Meeting for the project. HYDRAULICS AND WATER QUALITY 10. 11. 12. 13. Qualified Person For the purpose of certifying that the design of the rainwater harvesting system is in accordance with the requirements of this decision notice, a qualified person is considered to be a Registered Professional Engineer of Queensland (RPEQ), builder or plumber. Lawful Point of Discharge The applicant is advised that a lawful point of discharge for the development will need to be determined and demonstrated as part of a detailed design solution included with the Operational Works application. Bioretention Basin Educational Signage Suggested wording for the permanent educational signage required by this Decision Notice is as follows: “BIORETENTION BASIN - This bioretention basin reduces the pollution of our waterways by reducing the amount of heavy metals, litter, suspended solids, and nutrients discharged to (insert name of receiving waters)”. Waste Management Operational Phase For the purpose of demonstrating compliance with the waste management condition, the applicant is requested to contact Council’s Waste Management Branch. The respective waste collection vehicles (i.e. for collection of 2401 wheelie bins, 1100! and greater bulk bins) and their dimensions will be provided upon standard drawings when requested. Note: Council’s Waste Contract does not include the supply of waste compactor equipment. Only the service of a compactor is provided under the contract by Council. Subsequently the applicant must ensure that any compactor intended for use by the development can be serviced utilising the Contractor provided Waste Compactor Servicing Vehicle. ['9: PROPERTY NOTES | Not Applicable. | 10. PRELIMINARY APPROVAL OVERRIDING PLANNING SCHEME | Not Applicable. Page 12
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.