• Angled HumeGard® GPT Figure 4 – Dual Outlet HumeGard® GPT
The angled HumeGard® GPT (refer to Figure 3), was
developed to facilitate the replacement of junction
pits while still providing the treatment capabilities of
the original HumeGard® device. These units simply
alter the outlet location to allow for a change of pipe
direction of 45° or 90°. The Angled HumeGard® GPT
can be supplied in any of the standard unit sizes,
however, the designer must allow for a minor head
loss factor ‘k’ of 1.3 instead of 0.2 (which applies to the
standard HumeGard® GPT design).
• Dual Outlet HumeGard® GPT
The Dual Outlet HumeGard® GPT has been designed
to operate as a diversion structure upstream of natural
WSUD options such as constructed wetlands, ponds,
lakes, and bio-retention systems.
The units are designed such that one outlet conveys
the treated flow into the natural WSUD measure and
the standard outlet bypasses the excess flow around Inundation/tidal applications
the downstream system (refer to Figure 4). Dual Outlet
HumeGard® units are available in the same sizes as the The boom of the HumeGard® GPT enables the capture
standard HumeGard® units (refer Table 2 on page 4). of floating pollutants even at peak flows, often when
other fixed weir devices are in bypass mode. This
unique feature also makes the HumeGard® GPT ideal
Figure 3 – Angled HumeGard® GPT for applications that are subject to both tidal and tail
water effects.
In tidal applications the floating boom effectively traps
the floating pollutants and prevents the loss of the
gross pollutants from the system. In fixed weir devices,
previously trapped floating litter may be backwashed out
of the GPTs during the rising phase, to later bypass the
GPT during the falling phase of the tide. As this happens
twice daily, spring tides could quickly empty devices
relying upon a fixed weir.
Marine grade 316 stainless steel is used for all internals in
devices installed in tidal applications. In acidic/aggressive
environments, these may also be epoxy-coated. Contact
Humes Water Solutions for specific designs to suit
these applications.
A plinth can also be added to the false floor under the
boom to ensure sediment loads are captured during
inundation.