                  WQCP DESIGN ASSESSMENT CHECKLIST - BASED ON WBD WSUD TECHNICAL DESIGN GUIDELINES
                               WETLAND DESIGN ASSESSMENT CHECKLIST
Asset I.D.        Central Basin (WQCP)
Wetland           Refer to Operational Works Drawing No. 16-001014-400 Series and latest issue of SWMP Report No. 16-001014-01.
L   ti
Hydraulics:       Design operational flow (m3/s):            5.07         Above design flow (m3/s):                                          5.07
Area:             Catchment Area (ha):                       13.9         Wetland Area (ha):                                                0.194
TREATMENT                                                                                       Y     N   Comment
MUSIC modelling performed?                                                                      Y         Refer to latest issue of SWMP Report No. 16-001014-01.
INLET ZONE                                                                                      Y     N   Comment
Discharge pipe/structure to inlet zone sufficient for maximum design flow?                     N/A        Inlet zone/pond is not applicable as runoff is pretreated by GPT and Bioretention
                                                                                                          Basins with energy dissipaters at outlets into basin
Scour protection provided at inlet for inflow velocities?                                      N/A        Scour Protection provided for inflows into pond.


Configuration of inlet zone (aspect, depth and flows) allows settling of particles             N/A        No Inlet Zone provided, refer to comments above
>125μm?
Bypass weir incorporated into inlet zone?                                                      N/A        No Inlet Zone provided, refer to comments above


Bypass weir length sufficient to convey 'above design flow' ?                                  N/A        No Inlet Zone provided, refer to comments above


Bypass weir crest at macrophyte zone top of extended detention depth?                          N/A        No Inlet Zone provided, refer to comments above


Bypass channel has sufficient capacity to convey 'above design flow'?                          N/A        No Inlet Zone provided, refer to comments above


Bypass channel has sufficient scour protection for design velocities?                          N/A        No Inlet Zone provided, refer to comments above


Inlet zone connection to macrophyte zone overflow pit and connection pipe sized to             N/A        No Inlet Zone provided, refer to comments above
convey the design operation flow?
Inlet zone connection to macrophyte zone allows energy dissipation?                            N/A        No Inlet Zone provided, refer to comments above


Structure from inlet zone to macrophyte zone enables isolation of the macrophyte               N/A        No Inlet Zone provided, refer to comments above
zone for maintenance?
Inlet zone permanent pool level above macrophyte permanent pool level?                         N/A        No Inlet Zone provided, refer to comments above


Maintenance access allowed for into base of inlet zone?                                        N/A        No Inlet Zone provided, refer to comments above


Public safety design considerations included in inlet zone design?                             N/A        No Inlet Zone provided, refer to comments above


Where required, gross pollutant protection measures provided on inlet structures               Y          GPT's and upstream Bioretention Basins provided at inflow locations to WQCP
(both inflows and to macrophyte zone)
MACROPHYTE ZONE                                                                                Y      N   Comment


Extended detention depth >0.25m and <0.5m?                                                     Y          Extended Detention Depth = 400mm


Vegetation bands perpendicular to flow path?                                                   N/A        Not Applicable - A WQCP is proposed not a wetland. Furthermore the Pond is not
                                                                                                          required to meet site WQO's.
Appropriate range of macrophyte vegetation (ephemeral, shallow, marsh, deep                    N/A        Not Applicable - A WQCP is proposed not a wetland. Furthermore the Pond is not
marsh)?                                                                                                   required to meet site WQO's.
Sequencing of vegetation bands provides continuous gradient to open water zones?               N/A        Not Applicable - A WQCP is proposed not a wetland. Furthermore the Pond is not
                                                                                                          required to meet site WQO's.
Vegetation appropriate to selected band?                                                       N/A        Not Applicable - A WQCP is proposed not a wetland. Furthermore the Pond is not
                                                                                                          required to meet site WQO's.
Aspect ratio provides hydraulic efficiency =>0.5?                                              N/A        Not Applicable - A WQCP is proposed not a wetland. Furthermore the Pond is not
                                                                                                          required to meet site WQO's.
Velocities from inlet zone <0.05 m/s or scouring protection provided?                          Y          Scour Protection has been sized in accordance with QUDM (2013) specifications


Public safety design considerations included in macrophyte zone (i.e. batter slopes            Y          Refer to Operational Works Drawing No. 16-001014-400 Series. Proposed fencing
less than 5(H):1(V)?                                                                                      surrounding all edges of WQCP, slight grades for safety is also proposed, 2m
                                                                                                          benching around wetland is provided along macrophyte zone (with slopes larger than
                                                                                                          1:8)
Maintenance access provided into areas of the macrophyte zone (especially open                 Y          Access provided to WQCP
water zones)?
Safety audit of publicly accessible areas undertaken?                                          Y          Refer to Operational Works Drawing No. 16-001014-400 Series for safety features
                                                                                                          surrounding WQCP.
Freeboard provided above extended detention depth to define embankments?                       Y          300mm freeboard provided to minimum top of embankment level as per specifications
                                                                                                          provided in the latest issue of the SWMP Report No. 16-001014-01.

OUTLET STRUCTURES                                                                              Y      N   Comment


Riser outlet provided in macrophyte zone?                                                      Y          Refer to the latest issue of the SWMP Report No. 16-001014-01.


Notional detention time of 48-72 hours?                                                        Y          Nominal Detention Time of 55 hrs determined in latest issue of the SWMP Report No.
                                                                                                          16-001014-01.
Orifice configuration allows for a linear storage-discharge relationship for full range of     Y          Nominal Detention Time in the latest issue of the SWMP Report No. 16-001014-01.
the extended detention depth?
Maintenance drain provided?                                                                    Y          Pumping of deep water zones proposed.


Discharge pipe has sufficient capacity to convey maximum of either the maintenance             Y          Riser calculations confirm sufficiency of discharge pipe
drain flows or riser pipe flows with scour protection?
Protection against clogging of orifice provided on outlet structure?                           Y          Refer to Operational Works Drawing No. 16-001014-400 Series for details.


OTHER COMMENTS
Log in to download the original file

16-001014-02A (Ultimate SCMMP).pdf · 14.7 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.