Original source · versioned page text
16-001014-02A (Ultimate SCMMP)
Attached to the e-mail Operational Works Application OPW16/0203 - 4 of 4.
The original of this document is very large (14.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
WQCP DESIGN CALCULATIONS SUMMARY- BASED ON WBD WSUD TECHNICAL DESIGN GUIDELINES
Calculation Summary
Calculation Task Outcome Comments Check
Catchment Characteristics
Catchment area 13.9 ha Including Existing External Catchments
Catchment land use (i.e residential, commercial etc.) varying Refer to latest issue of the SWMP Report No. 16-001014-01.
Combined WQCP & detention basin is proposed. Energy Dissipaters and
Storm event entering inlet pond (minor or major) Major
velocity checks undertaken to ensure protection of WQCP.
Conceptual Design
Macrophyte zone area 1,940 m2 Area Required determined through MUSIC modelling
Permanent pool level of macrophye zone 99.2 m AHD
Extended detention depth (0.25-0.5m) 0.4 m
Notional detention time 55 hrs
1 Confirm Treatment Performance of Conceptual Design
Total suspended solids (Figure 6-2) 80% % removal Refer to latest issue of the SWMP Report No. 16-001014-01.
Total phosphorus (Figure 6-3) 69% % removal Refer to latest issue of the SWMP Report No. 16-001014-01.
Total nitrogen (Figure 6-4) 46% % removal Refer to latest issue of the SWMP Report No. 16-001014-01.
2 Determine Design Flows
Modelling Software Used XP-RAFTS Type Refer to latest issue of the SWMP Report No. 16-001014-01.
Verified with Rational Method Check? Yes Y/N Refer to latest issue of the SWMP Report No. 16-001014-01.
'Design operation flow' (1 year ARI) 2.575 m3/s
'Above design flow' (2-100 year ARI) 5.067 m3/s
3 Design Inlet Zone
Refer to Sedimentation Basin (Chapter 4) for detailed check sheet if applicable
Is a GPT required? YES Y/N Catchment larger than 5ha
Humegard HG45A or appropriate equivalent, maintenance access allowed
Suitable GPT selected and maintenance considered YES Y/N
for.
Is an Inlet Zone Required? NO Y/N
Inlet Zone Size
Not Inlet Zone proposed, however an upstream GPT and Bioretention
Target Sediment Size for Inlet Zone N/A um
Basins are proposed.
Capture efficiency N/A %
Inlet zone area (Figure 4.2 in Chapter 4) N/A m2
Vs > Vs:5yr N/A
Inlet Zone Connection to Macrophyte zone
Overflow pit crest level N/A m AHD
Overflow pit dimension N/A LxW
Provision of debris trap N/A
Connection pipe dimension N/A mm diam
Connection pipe invert level N/A m AHD
High Flow Bypass Weir
Weir Length N/A m
High flow bypass crest level (top of extended detention) N/A m AHD
Not Applicable - A WQCP is proposed not a wetland (the WQCP is not
4 Designing the Macrophyte Zone
required to achieve WQO's)
As specified in the approved Framework Letter Report (No.B14158.W.07L
dated 8 October 2015), this meets requirement for WQCP macrophyte area
Area of Macrophyte Zone 540 m2
(being above 20% of the WQCP water surface). Note that the WQCP is not
required to achieve WQO's.
Aspect Ratio N/A L:W
Not Applicable - A WQCP is proposed not a wetland (the WQCP is not
Hydraulic Efficiency N/A
required to achieve WQO's)
5 Design Macrophyte Zone Outlet
Riser Outlet
Target maximum discharge (Qmax) 0.004 m3/s
Uniform Detention Time Relationship for Riser 49 hrs
Maintenance Drain
Maintenance drainage rate (drain over 12hrs) N/A m3/s Pump out will be required for maintenance
Diameter of maintenance drain pipe N/A mm Pump out will be required for maintenance
Diameter of maintenance drain valve N/A mm Pump out will be required for maintenance
Discharge Pipe
Diameter of discharge pipe 825 mm
6 Design High Flow Bypass 'Channel'
Energy Dissipaters designed to reduce velocities, Velocity Checks
Longitudinal slope N/A %
undertaken through wetland,
Base width N/A m
Batter slopes N/A H:V
7 Verification Checks
Macrophyte zone re-suspension protection 0.001 m/s
WQCP was not modelled in MUSIC and is not required to meet site
Confirm Treatment Performance N/A Y/N
WQO's.
8 RPEQ Verification Matthew Starr MS (RPEQ 9485)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.