Original source · versioned page text
16-001014-02A (Ultimate SCMMP)
Attached to the e-mail Operational Works Application OPW16/0203 - 4 of 4.
The original of this document is very large (14.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
SAFETY IN DESIGN HAZARD REPORT
App? Action
Consideration Hazard / Comment Controlling Action Action By
Status
Existing site conditions:
Contaminated materials including biological N/A
hazards
Existing services including relocations Potential injury/death due to striking of Appropriate warning notes provided on Designer / Complete on
existing services located along roads, engineering plans. DBYD investigation Contractor plans/
external intersections undertaken and design has been
undertaken to minimise risk due to existing
Ongoing for
construction
services. Contractor to locate all services
prior to ground disturbance/excavation.
Existing site uses and users No existing users
Adjacent land uses and users Risk of unauthorised entry and works Contractor/Principal to provide adequate Contractor/ Prior to
near public road. site controls including fencing if required to Principal Construction
perimeter of the site to limit access and
reduce risks associated with unauthorised
entry
Geotechnical conditions and likely method of Conventional, however deep All works to be undertaken in accordance Contractor During
excavation excavations are likely and additional with standards and WH&S requirements. Construction
control measures may be required by
contractor
Ground water Likely to be encountered in low lying To be managed by contractor and Contractor/ During
areas and gullies. superintendent during construction. Superintend Construction
ent
Susceptibility to flooding including overland Overland flowpaths exist with the Gullies and channels to be avoid during Contractor During
flow paths and floodways potential for significant flooding along times of high rainfall Construction
the main gullies
Existing provision for access including traffic, Hazards associated with existing road Appropriate traffic management to be Contractor During
residential, pedestrian, equestrian, etc. surrounding the site. implemented by the contractor throughout Construction
the duration of the works
Existing bus routes and bus stops
Existing features of cultural, archaeological, None associated with Stage 1A
heritage and / or environmental significance Central Wetland
Design:
Document: QAF2024 Safety in Design Hazard Report – Generic
Revision 10 – 10/02/2015 Page 2 of 12
File: H:\B14\150-199\B14158.W\01 Final Layout Op Works\Checklists\B14158.W - Safety in Design_WQCP.docx [Update to show User's file] Calibre Consulting (Aust) Pty Ltd