SAFETY IN DESIGN HAZARD REPORT

                                                      App?                                                                                                                         Action
                  Consideration                                           Hazard / Comment                               Controlling Action                     Action By
                                                                                                                                                                                 Status

 Unusual or atypical design features                            Fall hazard associated with high            Safety fences to be provided where hazard         Designer/         During
                                                                retaining walls, deep excavations and       exists as per Operational Works Design            Landscape         Construction
                                                                works around services.                      Drawings. Engineering design to specify           Architect/Co
                                                                                                            interim star picket safety fencing for
                                                                                                           Operational Works drawings prior to
                                                                                                                                                              ntractor

                                                                                                            establishment of vegetation. Contractor and
                                                                                                            superintendent to identify risk prior to
                                                                                                            construction occurring.
 Construction:

 Method of construction                                         Conventional hazards associated with        All works to be undertaken in accordance          Contractor        During
                                                                subdivision works applies                   with the requirements of the subdivision                            Construction
                                                                                                           guidelines and operational works in
                                                                                                            accordance with WH&S requirements.
 Access                                                         Access to the site via public roads and     Engineering plans refer to provision of           Contractor        During
                                                                requires adequate traffic management        adequate traffic control by the contractor as                       Construction
                                                                                                           a part of the operational works in
                                                                                                            accordance with WH&S requirements
 Crane / Plant requirements                                     All hazards associated with plant           All works to be undertaken in accordance          Contractor        During
                                                                operations for subdivision works            with WH&S requirements including work                               Construction
                                                               applies                                     method statements for operation of plant as
                                                                                                            required
 Maintenance:

 Method of maintenance                                          Addressed in Concept Stormwater             All structures designed in accordance with        Designer          Complete
                                                                Management Construction and                 Council and Water by Design standards.
                                                               Maintenance Plan (Report No.                Engineering plans forwarded to Council for
                                                                B14158.W-05B dated November                 Operational Works approval. Appropriate
                                                                2015)                                       Maintenance measures outlined in report.
 Demolition:

 Method of demolition                                          N/A                                         Best Practice/ Compliance

 High Risk Construction Activities:

 A person could fall more than 2m                               Injury/Death resulting from falling from    Safety fencing to all walls over 1m specified     Designer/Co       Ongoing
                                                               retaining walls/deep excavations            on drawings unless appropriate landscape
                                                                                                            buffers provided. Contractor to ensure
                                                                                                                                                              ntractor

                                                                                                            adequate fall protection (temporary fencing)
Document: QAF2024 Safety in Design Hazard Report – Generic
Revision 10 – 10/02/2015                                                                                                                                                        Page 3 of 12
File: H:\B14\150-199\B14158.W\01 Final Layout Op Works\Checklists\B14158.W - Safety in Design_WQCP.docx [Update to show User's file]                        Calibre Consulting (Aust) Pty Ltd
Log in to download the original file

16-001014-02A (Ultimate SCMMP).pdf · 14.7 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.