Council archive · source document
Town Planning Assessment Report (3) · MCU26/0012
Streetscape and effect on AO14.1 Only one driveway and Complies.
traffic network crossover is provided.
PO13 The visual impact of AO14.2 Where the premises has Not applicable.
driveways on the streetscape and frontage to more than one formed
surrounding area is minimised and and sealed road and the roads have
significant adverse impacts on the differing orders in the Road
traffic network are avoided. Hierarchy, the driveway and
cross-over is provided on the
frontage with the lower order.
AO14.3 For corner lots, driveways Not applicable.
and crossovers are located in
accordance with Council's standard
drawings.
No change to the existing
AO14.4 If in the Rural zone or
driveway crossover is
Rural Residential zone, the
proposed.
driveway and cross-over is located
to provide minimum safe sight
distances in accordance with
Austroads.
Editor's Note - An operational works
application is required for a second driveway.
Bushfire Hazard Management AO15 Within a bushfire hazard This requirement can be
PO15 Where located in a Bushfire area where there is no reticulated conditioned.
Hazard Area as shown on the water supply, the premises has:
Bushfire Hazard Overlay Map in (a) an accessible dam,
Schedule 2 and not in a water swimming pool or water
service area, an adequate, reliable, tank available for
safely located and freely accessible firefighting purposes with
water supply is provided for fire an onsite water volume of
fighting purposes, which is in not less than 5,000 litres;
addition to day to day water supply. and
(b) a water supply outlet pipe
50 millimetres in diameter
and fitted with a standard
fire brigade fitting
connected to the water
supply (other than where
the water supply is in a
swimming pool or dam).
Editor’s Note — Water supply capacity for
firefighting purposes is in addition to water
supply capacity for household use.
Flood Hazards AO16.1 Where the development is Not applicable.
PO16 Development is designed located in the Flood Hazard Area as
and sited to ensure risk to people shown on Flood Hazard Overlay
and property from flooding is Map in Schedule 2, the finished
floor level of habitable rooms is at
26
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Town Planning Assessment Report (3).pdfRelated documentApplication case desk ↗
Town Planning Assessment Report (3).pdfRelated documentApplication case desk ↗
About this file
- File size
- 8.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.