Council archive · source document
AS PUBLISHED - Information Request - 132008.299.02
4.1. Vegetation with vertical scale to provide screening/buffering to reduce bulk and
scale of the built form when viewed from the street and adjacent properties.
4.2. Planting location and schedule is to provide a mix of species in accordance with
the preferred plant species list in PSP2.
4.3. All landscape areas must allow for deep planting in natural ground unobstructed
by footings associated with side and rear boundary walls.
Item - Setbacks
AO14.1 Buildings and structures meet the following minimum boundary setbacks:
a. for frontages - 6 metres
b. for side boundaries -
i. 1.5 metres setback up to 4.5 metres height;
ii. 2 metres setback between 4.5 metres and 7.5 metres height; and
iii. 2.5 metres where above 7.5 metres height
c. for the rear boundary - 6 metres
Acceptable Outcome AO14.1 and Performance Outcome PO14 of the Medium Density
Residential Zone Code include setback requirements for buildings and structures that seek to
achieve a high level of amenity for site users and users of adjoining premises. Setbacks are
to allow for space and landscaping to be provided between buildings including adequate area
at ground level for landscaping.
Lot 3 on SP228958 contains two frontages and 1 side boundary (eastern boundary) which is
required to provide a 6.0 metre and 1.5 /2.0 metre setback respectively. Existing development
within Lot 3 is lower in building height and scale and is setback 2.0 metres to the unformed
laneway.
Information Required
5. The proposed setback of 1.5 metres which only contains paving is not supported and
does not provide sufficient setback to satisfy PO14. Provide amended plans and
elevations which increase the setback which includes landscaping including trees and
shrubs as required under PO14.
Item – Acoustic matters
6. The Report is based upon site architectural plans that differ to those submitted with the
development application. Update the report to represent the plans upon which the
application was made.
7. Clarify how the ambient noise data obtained by the noise logger on the site was adjusted
for extraneous noise and as to whether this included insect noise and whether the
measurement equipment included a frequency analyser to permit assessment of insect
noise contribution.
8. Clarify/provide the source and meteorological data used to exclude weather affected
noise measurements.
(i) Clarify the location of the noise logger with respect to the adjacent concrete wall
and whether the equipment location was free field.
(ii) In respect to noise criteria, include assessment in respect to Sleep Disturbance
and the LAmax parameter.
(iii) Provide assessment of the cumulative noise impact of the development in regard
to both time varying noise and continuous noise.
Page 3 of 6
See the original