Water Supply and Sewerage Analysis
2 Noosa on Weyba Population
Unitywater utilise an Equivalent Person (EP) population as the basis for their water supply and sewerage
planning.
The proposed development will occur in precincts comprising of a mix of residential uses, detached lots and
multi residential units and aged care facilities. In addition a portion of the development will comprise of non-
residential use; retail and leisure. The proposed development is detailed in Noosa on Weyba Precinct
Structure Plan),Appendix B. The adopted layout forms the basis of the development of an EP population for
the Noosa on Weyba development.
Based on the relevant Council planning and projected lot yields an EP loading was developed for the site.
The EPs developed for this analysis are indicative of the total density expected on the site and are detailed
in Table 2-1.
Table 2-1 Noosa on Weyba Population Projections
Quantity EP Density Adopted EP
Residential Lots 549 lots 3.3 EP x lot 1,574
Mixed Use Residential
2.5 EP x lot (assumed 2
(Townhouses/Units/Retirement 327 Units 752
bedroom unit)
Village)
2
Non Residential 4,435m GFA 100 EP per ha 44
TOTAL 2,370
Northbrook Corporation Pty. Ltd. Version 4 17 September 2013
5101-19 Commercial in Confidence Page 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 15- Amended Water Supply and Sewerage Analysis MCU12/0208Related documentApplication case desk ↗
About this file
- File size
- 11.7 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.