Original source · versioned page text
Attachment 4 - Existing_Acoustic_Environment (22.01.20)
3.2 TYPICAL NOISE TARGETS
In the absence of Council Conditions of Consent, the following are referenced for information as typical
noise targets.
3.2.1 Loading Dock Impacts (Trolley collection, mech. plant, compactor etc.)
Table 1 – EPP Noise 2008, Schedule 1 - Acoustic Quality Objectives for Residential
Sensitive Time of Day Criteria (measured at the receptor)
receptor dB(A)
LAeq,adj,1hr1 LA1,adj,1hr2
daytime and evening 35 45
dwelling (indoors) (habitable spaces)
night-time (sleeping areas) 30 40
1
Acoustic descriptor/noise target for continuous noise sources (e.g. mechanical plant).
2
Acoustic descriptor/noise target for transient impacts arising from loading dock activities (e.g. truck
movements, reversing alarms, compactor, trolley etc.).
3.2.2 Traffic
Generally, the traffic noise impacts onto residential buildings are assessed against indoor noise targets given
in Australian Standard AS 2107-2016 as shown in Table 2. The table references houses and apartments near
major roads. Near minor roads, the targets would be 5dB(A) below the upper limit.
Table 2 -AS 2107 Recommended Design Sound Levels for Residential
Type of occupancy/activity Indoor Noise Limit, Leq,T
(dBA)
Living and Work areas 35 to 45
Sleeping areas (night time) 35 to 40
I:\Jobs\2019\20191414\20191414.1\20200115SSA_R2_Existing_Acoustic_Environment.docx 7