NATURAL HAZARDS OVERLAY CODE
Performance Criteria and Acceptable Solutions

eae See

   

ACCEPTABLE SOLUTIONS

SOLUTIONS"

 

COMMENTS

‘Bcames company

COUNCIL USE ONLY

 

 

 

 

 

 

General
01 S14 v The proposed development is not located in a landslide hazard
Development is located to ensure it does not | The proposed development is not located in a area.
compromise the safety of people, property or | landslide hazard area as indicated on Overlay
hazardous materials manufactured or stored in bulk | Maps OM1.3-OM9.327; or
by increasing risk of landslide; and
$1.2
The development site is not subject to landslide, v Slopes on the site are less than 15%.
either internally or from sloping land above the site
{ie. slopes are less than 15% (1:6.6)} and
$1.3
Development, including necessary earthworks NA The subject site is not located within Noosa Springs.
within Precinct F of the Noosa Springs site,
improves the stability of any non-natural landform
so it is not at risk from landslide either on the site or
from sloping land above the site.
02 $2.1
Development, including accessways is designed | No solution provided v The proposal is responsive to the topography of the site.
and constructed to— Retaining walls have been included where required to ensure
a) minimise impacts on the natural landform; safety within the site, however the majority of the proposed
b) minimise risk to people and property from development is responsive to the natural topography of the site,
landslide; and will not result in significant impacts to the natural landform
c) avoid any potential instability and associated
problems, including long term stability of the site
and long term stability of the development.
Protection of Infrastructure and Community
Uses
03 $3.1 .
Community Uses and Infrastructure Uses, | Community Uses and Infrastructure Uses are v No part of the subject site is identified as being within a landslide

including that identified below, are able to function
effectively during and immediately after landslide
events—

 

not located in a landslide hazard area as indicated
on Overlay Maps OM1.3- OM9.3; or

 

 

hazard area.

 

 

 

4 Solution: | ¥ = Acceptable Solution

"AIS = Alternative Solution

N/A = Not applicable to this proposal

20517 - Essence of Peregian

Appendix Q

20517_naturalhazardsOverlayCode_FINAL_mrc.doc

Page 1

Used in these records

About this file

File size
6.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

20517 App Q.pdf [As Published].pdf · 6.8 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.