Council archive · source document
20517 App Q.pdf [As Published] · 132007.1259
NATURAL HAZARDS OVERLAY CODE Performance Criteria and Acceptable Solutions PERFORMANCE CRITERIA ) Emergency service facilities; Hospitals; Education Type 4 uses, including stores for valuable records or items of historic or cultural significance; and d) Service and utility uses, including electricity substations, major electrical depots and water treatment plants. a yea ACCEPTABLE SOLUTIONS SOLUTIONS’ oe) a RS) COUNCIL USE ONLY $3.2 The community infrastructure, development— No community infrastructure has been incorporated into this a) does not result in any new building work other proposal. than an addition to an existing building; b) does not involve vegetation clearing; and c) does not alter ground levels or stormwater conditions; or $3.3 The development includes measures that ensure— v The subject site is not identified as being within a landslide hazard a) _ the long term stability of the site; b) access to the site will not be impeded by a) landslide event; and c) the community infrastructure will not be adversely affected by landslides originating on sloping land above the site28. area. New Uses 04 $41 AIS Part of the site is located within a Medium Bushfire Hazard Area. The proposed use does not compromise the safety | The use is sited on land that is not in a Medium or The majority of the proposed development is not located within this of people or property from bushfire. High Bushfire Hazard Area29. area and has been designed to mitigate the effects of Bushfire. Protection of Infrastructure and Community Uses NIA No community or infrastructure uses form a part of this proposal. 05 $5.4 Community Uses and Infrastructure Uses, | Community Uses and Infrastructure Uses are including that identified below, are able to function | not located in a High or Medium Bushfire Hazard effectively during and immediately after bushfire | Area identified on Overlay Maps OM1.4 to OM9.4; events— or a) Emergency service facilities; b) Hospitals; $5.2 c) Education Type 4 uses, including stores for | Building work will not involve more than an NIA valuable records or items of historic or cultural significance; and’ d) Service and utility uses, including electricity substations, major electrical depots and water additional 20m2 of Gross Floor Area to an existing building; or 1 Solution: | ¥ = Acceptable Solution A/S = Alternative Solution N/A = Not applicable to this proposal 20517 ~ Essence of Peregian Appendix Q 20517_naturalhazardsOverlayCode_FINAL_mrc.doc Page 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20517 App Q.pdf [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.