(As Published) - Referral Agency Response - Planning ERR25 0013

of 4

Page text shows just the words. Original shows the document exactly as it was published.

                        Landscaping
                 8.     Where excavations result in a cut face greater than 0.5m, suitable landscaping is to be
                        installed to soften the visual impacts of the excavations to the Noosa Waters’ Canal for
                        the full length of the cut face. Landscaping is to be of a suitable species and in
                        accordance with Noosa Plan 2020 Planning Scheme Policy PSP2 Landscaping.
                        Revetment Wall / Flood Storage
                 9.     All works within the 4.5m setback from the revetment wall must be carried out generally
                        in accordance with:
                        a.      Lindsay Consulting’s Proposed Works Plan (25-0753-F11, Rev. A) dated 5
                                December 2025; and
                        b.      Lindsay Consulting’s Flood Volume Calcs (25-0753-F11, Rev. A) dated 5
                                December 2025
                 10.    All works for the purpose of increasing available flood storage must be located within
                        the 4.5m setback from the revetment wall.
                 11.    Certification of the completed works within the 4.5m setback from the revetment wall
                        must be submitted to Council within 3 months of the completion of the works. The
                        certification must be prepared by a RPEQ (Registered Professional Engineer of
                        Queensland) and state that the works:
                        a.      Have not reduced the amount of available flood storage within the 4.5m setback
                                from the revetment wall;
                        b.      Have not negatively impacted the stability of the revetment wall or negatively
                                impacted the associated membrane;
                        c.      Have not reduced the available flood storage within the lot from the profile as
                                described in The Noosa Plan 2020 – Low Density Residential Zone Code; and
                        d.      Meet the relevant conditions of this approval.
                 5.     REASONS FOR REFERRAL AGENCY’S DECISION

                 The proposal is subject to specific built form parameters outlined in The Noosa Plan (26
                 September 2025).
                 6.     REFERENCE DOCUMENT

                  Plan No.             Rev. Plan/Document Name                                    Date

                  220813               -    Flood Storage Calculations and Geotechnical Report, 24           July
                                            prepared by Lindsay Consulting                      2022

                  25-0753-F11          A    Proposed Works        Plan,   prepared   by   Lindsay 5 December
                                            Consulting                                            2025

                  25-0753-F11          A    Flood Volume Calcs, prepared by Lindsay Consulting    5 December
                                                                                                  2025




                                                                                                         Page 3 of 4
Document Set ID: 24415728
Version: 5, Version Date: 08/01/2026
Log in to download the original file

(As Published) - Referral Agency Response - Planning ERR25 0013.pdf · 114 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.