Original source · versioned page text
Code Assessment
Plot Ratio AO11 For a dwelling house, plot Alternate Solution
PO11 Plot ratio of development: ratio of development does not Refer report.
exceed 0.4:1
1. does not exceed 0.4:1; or
2. for small dwellings or for
development which provides
a ratio of at least three small
dwellings to one other
dwelling, does not exceed
0.5:1.
Building Setback AO12.1 Buildings and structures Alternate solution - partially
PO12 Buildings and structures are meet the following minimum complies
designed and sited to: boundary setbacks: Refer report.
1. provide a high level of 1. for frontages — 6 metres
amenity to users of the 2. for side boundaries—
subject site and adjoining 1. 1.5 metres setback up
premises, including provision to 4.5 metres height;
of visual and acoustic
2. 2 metres setback
privacy;
between 4.5 metres
2. not unreasonably obstruct and 7.5 metres height;
views or cause overlooking and
of private open space or
3. 2.5 metres where
habitable areas of adjoining
above 7.5 metres
premises;
height
3. provide adequate distance
3. for the rear boundary - 6
from adjoining land uses;
metres
4. preserve existing vegetation
that will help buffer
development; AO12.2 The front 6 metres of the Complies with AO12.2
property is landscaped open Landscaping is provided within
5. allow for space and
space, provided that uncovered the front 6 metres of the
landscaping to be provided
visitor parking, or swimming pools property where practical.
between buildings including
protruding no more than 1 metre
adequate area at ground
above the ground level, can be as
level for landscaping with
close as 2 metres from the front
trees, shrubs, outdoor living
boundary.
and utilities;
6. be consistent with the Not applicable
predominant character of the AO12.3 Relocatable homes are
surrounding area; and set back not less than:
7. protect the natural character (a) 6 metres from a road
and avoid adverse impacts frontage;
on ecologically important (b) 1.5 metres from any other
areas such as national parks, site boundary; and
waterways and wetlands. (c) 3 metres from an internal
road
AO12.4 Buildings and structures Not applicable
on premises with frontage to the
Noosa River system are set back
not less than 10 metres from
5
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.