5.3 Bushfire Attack Levels and Construction Standards
5.3.1 Background
Australian Standard 3959 (2009) Construction of buildings in bushfire-prone areas provides
minimum construction standards for new dwellings in designated Bushfire Prone Areas. The
construction standards are intended to improve the performance of buildings subjected
to burning debris, radiant heat or flame contact. The AS3959- 2009 methodology
prescribes Bushfire Attack Levels (BAL’s) to the facades of proposed buildings to which
corresponding construction safety standards are applied. AS3959-2009 defines Bushfire
Attack Levels as:
‘A means of measuring the severity of a building’s potential exposure to ember
attack, radiant heat and direct flame contact, using increments of radiant heat
expressed in kilowatts per metre squared, which is the basis for establishing the
requirements for construction to improve protection of building elements from
attack by bushfire.’
Table 9 describes the range of available BAL’s and their related degree of potential
severity.
Table 9 – Description of Bushfire Attack Levels (BALs) (AS3959- 2009)
Heat flux exposure thresholds of Description of predicted Construction Section
Bushfire Attack
classified vegetation within bushfire attack and levels of
Level (BAL)
100m of the site exposure
There is insufficient risk to
BAL- LOW See Clause 2.2.3.2 warrant specific construction 4
requirements
BAL – 12.5 <12.5kW/m2 Ember attack 3 and 5
Increasing levels of ember
>12.5kW/ m2 attack and burning debris
BAL - 19 ignited by windborne embers 3 and 6
<19kW/m2 together with increasing heat
flux
Increasing levels of ember
>19kW/ m2 attack and burning debris
BAL - 29 ignited by windborne embers 3 and 7
<29kW/m2 together with increasing heat
flux
Increasing levels of ember
attack and burning debris
>29kW/ m2 ignited by windborne embers
BAL - 40 together with increasing heat 3 and 8
<40kW/m2 flux with the increased
likelihood of exposure to
flames
Direct exposure to flames
BAL - FZ >40kW/m2 from fire front in addition to 3 and 9
heat flux and ember attack
Bushfire Management Plan
February 2015 Page 24
215 David Low Way, Peregian Beach
Scanlon Property Group
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.