calculations are presented in Attachment D. To achieve the internal acoustic quality objective of 40 dBA
LA1,adj,1hour, upgrades to the external facade of the Linea Houses would include the following:
   • Bedroom 1:
      ○  External Walls: Lightweight external walls (Rw 41): 6mm fibre cement sheeting over minimum
         76mm wide steel studwork (or 90mm wide timber studwork), lined internally with 10mm
         plasterboard sheeting and 50mm glasswool insulation in the cavity.
     ○ Roof (Rw 41): Pitched metal roof with internal 10mm plasterboard sheeting for the ceiling and
         50mm glasswool insulation in the cavity.
     ○ External Glazing (Rw 33): Acoustically rated glazing system including frame and seals, which may
         entail 10mm think laminated glass.
   • Living Room:
     ○ External Walls: Lightweight external walls (Rw 41): 6mm fibre cement sheeting over minimum
         76mm wide steel studwork (or 90mm wide timber studwork), lined internally with 10mm
         plasterboard sheeting and 50mm glasswool insulation in the cavity.
     ○ External Glazing (Rw 23): Standard glazing.
   • Bedroom 2:
     ○ External Walls: Lightweight external walls (Rw 41): 6mm fibre cement sheeting over minimum
         76mm wide steel studwork (or 90mm wide timber studwork), lined internally with 10mm
         plasterboard sheeting and 50mm glasswool insulation in the cavity.
     ○ Roof (Rw 41): Pitched metal roof with internal 10mm plasterboard sheeting for the ceiling and
         50mm glasswool insulation in the cavity.
     ○ External Glazing (Rw 23): Standard glazing.

The recommended glazing upgrades are presented in Figure 4.1 (note the Hotel is located to the right-hand
side of this plan).




8816R02V01.docx                                                                                         9
Log in to download the original file

Information Response - Email 1 of 2 MCU16_0153 & REC16_0041.pdf · 22.0 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.