Skip to the record
Search everything, all in one place.

Council archive · source document

Proposal Plans · MCU25/0054

of 26

Check the original when the exact wording matters.

Plans and drawings: the text below has words only, no drawings.

Very large file (17.0 MB): may take a few minutes to open.

Log in to see the plans as drawn
♻ play your part - print on recycled paper
                                                                                                                                                                                                                                                                                                                     5m          4         3          2         1




                                              Building height and setback line shown from typical NGL                                                                                                                                             COLORBOND® ultra steel rebated gutter/flashing to be
                                              1.365m AHD                                                                                                                                                                                          fixed in accordance with manufacturers specifications and
                                                                                                                                                                                                                                                  hydraulic engineers detail.

                                              STRATCO 200mm Edge gutters in COLORBOND® steel




                                                                                                          Boundary




                                                                                                                                                                                                                               Boundary
                                              to be fixed in accordance with manufacturers
                                              specifications. 180 x 30mm h3 treated primed timber                                                                                                                                                 COLORBOND® steel Custom Orb oof sheeting to be fixed
                                              fascia. Gutters to have 10mm spacers to fascia to provide                                                                                                                                           in accordance with manufacturers specifications.
                                              overflow point.                                                                                             12,836
                                                                                                                            3,700                                             10.0°                 3,700
                                                                                                                          bdy to wall                                                             bdy to wall
                                                                                                                                                                                                  11,850
                                           11,490
                                           Ceiling
                                                                                                                                                                                                                                                  Suspended concrete green roof to be in accordance with
                                                                                                                                                                                                                                                  structural engineers design and detail. Planter to have
                                                                                                                                                                                                                                                  40mm upvc drainage outlets and Soprema Landscape
                                                                                                                       2,500                                                                             2,500                                    waterproofing system with premium soil fill and plants to
                                              Knotwood Hinoki 100 x 50mm @150mm cts. to provide                      bdy to wall                                                                       bdy to wall




                                                                                                                                                                                                                                          2,740
                                              balustrade in accordance with ABCB Housing Provisions                                                                                                                                               landscapers specifications.
                                              Standard 2022 : 11.3. Balustrade to be a min. 1000mm                                                                                                                                                Concrete block wall to be in accordance with structural
                                              high above finished floor level.                                                                                                                                                                    engineers design and detail. Provide acrylic render system
                                           8,750                                                                                                                                                                                                  with fine sand finish and painted with selected colour in
                                           Second floor                                                                                                                                                                                           accordance with final colour selections to exposed wall
                                                                                                                                                                                                                                                  surfaces.
                                                                                                                      2,030                                                                            2,930
                                              HDG steel spiral stairs to be in accordance with                        bdy to                                                                       bdy to battens                                 Suspended concrete green roof to be in accordance with
                                              manufacturers design and detail. Stairs to be in                       battens
                                                                                                                                                                                                                                                  structural engineers design and detail. Planter to have




                                                                                                                                                                                                                                          3,150
                                              accordance with ABCB Housing Provisions Standard
                                                                                                                                                                                                                                                  40mm upvc drainage outlets and Soprema Landscape
                                              2022 : 11.2 Stairs and handrail to have selected powder
                                                                                                                                                                                                                                                  waterproofing system with premium soil fill and plants to
                                              coated finish with 75 x 25mm Knotwood Hinoki hit & miss
                                                                                                                                                                                                                                                  landscapers specifications.
                                              batten balustrade screen to spiral staircase.
                                           5,600
                                           First floor
                                                                                                                                                                                                                                                  Knotwood Hinoki 150 x 25mm battens @150mm cts. to
                                                                                                                 2,500                                                                        4,540
                                              Knotwood Hinoki 150 x 25mm battens @150mm cts. to                                                                                                                                                   provide privacy screening.
                                                                                                          4,280bdy to wall                                                                bdy to column          4,280
                                              provide privacy screening.




                                                                                                                                                                                                                                          2,900
                                                                                                                                                                   3,280                                          3,280

                                           2,700
                                           Ground floor

                                                                                                                                        1,680



                                              Concrete block wall to be in accordance with structural
                                              engineers design and detail. Provide acrylic render
                                              system with fine sand finish and painted with selected
                                              colour in accordance with final colour selections to
                                              exposed wall surfaces.




                           Western Elevation
 W                                                      1:100
                                                                                                                                                                                                                                                                                                        /Users/benthornton/Documents/Cadfiles/2502 - Palazzesi - 20 William/
                                                                                                                                                                                                                                                                                                                                               Archicad/25032025/2502.pln
                    sbt designs pty ltd t/a
                    Skale Building Design                                         project         Duplex Residence                              lot no.                               3    DA02      Development application issue                                                                 25/3/2025
                                                                                                                                                                                                                                                                                                               project number
                    Mobile: 0412 025 657
                                                                                  for             Ross Palazzesi                                plan no.                   RP 63813        DA01      Development application issue                                                                  4/3/2025
                                                                                                                                                                                                                                                                                                               2502
skale skale.com.au
                                                                                                                                                                                           CD07      Conceptual design issue                                                                       26/2/2025
                                                                                                  20 William Street                             drawn                            BT
                                                                                                                                                                                           CD06      Conceptual design issue                                                                       25/2/2025
                                                                                                                                                                                                                                                                                                               drawing number
                    [email protected]
  building design   A.C.N. 123 976 296 QBCC: 1143 609                             at              Noosaville                                    scale       (A3)              1:100         Rev      Details                                                                                           Date    10           DA02                    © Skale Building Design

Used in these records

About this file

File size
17.0 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Proposal Plans.pdf · 17.0 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.