Building height and setback line shown from typical NGL
1.365m AHD
Skypan glass skylights installed in accordance with
manufacturer's design and detail. STRATCO 200mm Edge gutters in COLORBOND® steel
to be fixed in accordance with manufacturers
COLORBOND® steel Custom Orb oof sheeting to be fixed specifications. 180 x 30mm h3 treated primed timber
in accordance with manufacturers specifications. fascia. Gutters to have 10mm spacers to fascia to provide
Boundary overflow point.
Boundary
COLORBOND® ultra steel rebated gutter/flashing to be
fixed in accordance with manufacturers specifications and 10.0° 10.0°
hydraulic engineers detail.
10,000 8,717
bdy to wall bdy to wall
Knotwood Hinoki 100 x 50mm @150mm cts. to provide Concrete block wall to be in accordance with structural
balustrade in accordance with ABCB Housing Provisions engineers design and detail. Provide acrylic render
Standard 2022 : 11.3. Balustrade to be a min. 1000mm system with fine sand finish and painted with selected
high above finished floor level. colour in accordance with final colour selections to
exposed wall surfaces.
6,153
bdy to stairs
HDG steel spiral stairs to be in accordance with
manufacturers design and detail. Stairs to be in accordance
with ABCB Housing Provisions Standard 2022 : 11.2 Stairs
and handrail to have selected powder coated finish with 75
x 25mm Knotwood Hinoki hit & miss batten balustrade
screen to spiral staircase.
Knotwood Hinoki 150 x 25mm battens @150mm cts. to 4,869
provide privacy screening. bdy to stairs
HDG steel spiral stairs to be in accordance with
manufacturers design and detail. Stairs to be in
Flow Defence Passive flood barrier to be installed in accordance with ABCB Housing Provisions Standard
accordance with manufacturers specifications. Flood barrier 2022 : 11.2 Stairs and handrail to have selected powder
to achieve active protection height of 2.7m AHD. coated finish with 75 x 25mm Knotwood Hinoki hit & miss
batten balustrade screen to spiral staircase.
Concrete driveway to be in accordance with structural Knotwood Hinoki 150 x 25mm battens @150mm cts. to
engineers design and detail. Provide selected coloured/ provide privacy screening.
feature aggregate blend to manufacturers specifications.
Driveway to comply with AS2890.1. Driveway to connect to
existing crossover in accordance with local authority
regulations. Driveway grades to be in accordance with
AS2890.1.
Southern Elevation
S 1:100
/Users/benthornton/Documents/Cadfiles/2502 - Palazzesi - 20 William/
Archicad/25032025/2502.pln
sbt designs pty ltd t/a
Skale Building Design project Duplex Residence lot no. 3 DA02 Development application issue 25/3/2025
project number
Mobile: 0412 025 657
for Ross Palazzesi plan no. RP 63813 DA01 Development application issue 4/3/2025
2502
skale skale.com.au
CD07 Conceptual design issue 26/2/2025
20 William Street drawn BT
CD06 Conceptual design issue 25/2/2025
drawing number
[email protected]
building design A.C.N. 123 976 296 QBCC: 1143 609 at Noosaville scale (A3) 1:100 Rev Details Date 11 DA02 © Skale Building Design
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Proposal Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 17.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.