Council archive · source document
07/0738 - Response to Information Request [As Published] · 132007.738
-2- Comment: In accordance with Probable Solution $15.3 of the Driveways and Carparking Code, end of trip facilities are only required for the Industrial Use and are not required for the café. Each industrial tenancy will be provided with end-of trip facilities. Attached in Appendix A is an indicative floor plan indicating the proposed provision of end-of-trip facilities to be provided within each separate tenancy. Issue 4 i Please provide a noise and lighting assessment report prepared by a suitably qualified person to ! address the acoustic and lighting amenity issues raised in the Business Uses Code (specifically Qutcomes 03 and O11) with respect to the residential areas to the west of the site and any noise attenuation measures that may be necessary. | The acoustic report shall assess all potential noise sources and demonstrate how the development will not cause — e Excessive noise under Council's Local Law No. 12 - Control of Nuisances. , © Untawful environmental nuisance under the Environmental Protection Regulation 1998. i “It is noted that the existing development approval for the site (23074DA) involved a report of this ‘nature, prepared by,Cardno. MBK (Qld) Pty Ltd,.and. this may. be revised forthe new. proposal. Comment: A Noise and Lighting Assessment Report prepared by Cardno is attached in Appendix D. This report confirms that the development will not result in any detrimental noise or lighting impacts. [1sSue's”” we ee au ee cm ee (It is noted that the development is adjacent to bushfire hazard and areas mapped in The Noosa Plan — and includes significant buildings between these areas and the access/egress provided via Gateway . ‘Drive. Please provide a bushfire management report for the site prepared by a suitably qualified . person and include any necessary recommendations on amended plans. wee ee Comment: The Noosa Plan does not include the subject site within a bushfire hazard area nor does any boundary of the site adjoin an area designated as bushfire hazard area. As such and given that the application is code assessable, no need or requirement exists for provision of a bushfire management report. LAND DEVELOPMENT ‘Wie 6 wee ae - wee ee Please provide a detailed survey plan, prepared by a licensed land surveyor, of all existing features on site and on land adjacent to the site, such as any services (including their alignment, size, depth, invert level, etc) vegetation, topography of the land (contours) and any other relevant information. All level information shall be to the Australian Height Datum (AHD). Existing services that run through the site (including any easements) and existing vegetation to be retained should all be shown on the amended proposal plans. Where existing services are to be extended or new services are to be provided within the site, they should also be shown on the proposal plan to ensure that the proposed buildings do not conflict with ° such services. . d Comment: Existing contours and relevant services are shown on the plans prepared by Callaghan & Toth attached in Appendix E. These plans also provide details of the proposed finished site levels and sewer and stormwater layout.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0738 - Response to Information Request [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.