Council archive · source document
07/0738 - Response to Information Request [As Published] · 132007.738
: Q> Santee, Therefore, the traffic generated in the AM and PM peak hours would have limited impact on the external road network and thus not require any upgrading of external road networks, so a detailed traffic report would not be necessary in this situation. Council Condition - 7 “Demonstrate that the car park areas (including all car park spaces, manoeuvring areas, and driveways) comply with Australian Standard AS2890.1 — Off-street Car Parking. Some issues to be addressed include: Response The car parking area has been designed in accordance with Australian Standard 2890. 1:2004 Parking Facilities, Part 1: Off-street Car Parking. All circulation aisles have been designed such that they are one-way and have a width of 5.8m. Since the users of the development are considered to be defined as User Class 3 (customers) and Class 1 (staff) this is considered to be appropriate. The minimum car parking space width specified for these users is 2.4m for staff and 2.6m for customers. As spaces of both widths are to be provided throughout the site, the employee spaces may be designated as such though the use of line marking and signage. All of the 90 degree angle spaces that are located through the centre of the site will have a length of 4.8m. This is appropriate given that these vehicles are abie to overhang into the central area. The spaces located immediately in front of the industrial buildings are proposed to have a length of 5.4m. Drawings CE780062-1 (refer Appendix A) shows the swept paths of a car at the intended bay areas which may be considered the more difficult of spaces to park in. Council Condition — 7.1 “Demonstrate the adequate sight lines are available to and from Gateway Drive and internal to the site in accordance with section 3.2.4 of AS2890. 1.” Response Since the proposed site is at the end of a cul-de-sac and has a roundabout controlling movement priority, the design speeds to the site would be approximately 20km/hr and from the site even less. Furthermore, the bend in Gateway Drive approximately 150m south of the roundabout will limit the speed approaching the site. Therefore, to demonstrate the adequate sight lines is considered unnecessary as the sight distance required for speeds of 20km/h and lower are not even included in section 3.2.4 of AS2890.1. Nevertheless, the sight distance available at the site access intersection with Gateway Drive with the highest conflict speed is illustrated for a design speed of 40km/h on Drawing Number CE780062-2 which is included at Appendix A and is considered to be appropriate. Council Condition - 7.2 “Demonstrating that a vehicle queue length on all driveways of at least 12m is provided (Measured from the Gateway Drive property boundary into the site) whereby no parking spaces or manoeuvring areas are permitted in the order to allow the free influx of traffic in accordance with Section 3.4 of AS2890.1.” Response Table 3.3 of AS2890.1, states that the minimum queuing length that should be accommodated shall be the greater of a minimum of two cars or 3% of the capacity of the car park for not more than 100 cars. Therefore, for this development the required queue length at the entrance to the site should be able to store three vehicle tengths, with three car lengths for the 88 spaces to the east and 1 car length for the 9 spaces to the west. Drawing Number CE780062-2 (refer Appendix A) shows that these queues can be accommodated at the entry to the site. G:\780062 Noosaville Industria\780062 DRAFT CEO RFI ON_20080220.doc
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0738 - Response to Information Request [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.