Skip to the record
Search everything, all in one place.

Council archive · source document

07/0738 - Response to Information Request [As Published] · 132007.738

of 63

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

www.callaghanandtoth.com.au
ABN No. 57690359242

6/41 Sunshine Beach Roa Noosa Junction
P.O, Box 2305 Noosa Heads 4567
0754749081 Fax 0734749041

E-mail [email protected]

Callaghan & Toth
Civil, Environmental & Hydraulic Engineers

12" December 2007 . File No: 06105

The Chief Executive Officer
Noosa Council

PO Box 141

Tewantin 4565

Attention: Denis Wallace
Dear Sir,

INFORMATION REQUEST DATED 4™ JUNE 2007 FOR APPLICATION 07/0138 AT 64
GATEWAY DRIVE NOOSAVILLE

On behalf of Mintgrove Pty Ltd, below we offer our repose to items 11, 12, 13, 14,
15, 16, 17, 18, 19 & 20 of the above information request.

11. The enclosed plan 06105-1A shows finalised floor levels of the buildings and
carpark. The plan also shows one east west section and one north south
section which reflect the finish levels in relation to the natural surface.

12. Plan 06105-1A also shows the extents of retaining walls and cut & fill batters.
The volume of earthworks is likely to be in the order of 1,500m° cut and
5,000m* fill.

13. Plan 06105-1A has notes which list the proposed height of retaining walls.

14. Plan 06105-2 has the main sanitary drainage lines shown with invert levels
and surface levels which indicate that the site can connect by gravity to
Council's sewers.

15. Plan 06105-2 shows access to sewer in the south east corner and the North
West corner.

16. Plan 06105-1A shows the proposed location of the electrical substation and
the location of the fire hydrant booster boxes.

17. Previous indicative river flood free floor height issued by Noosa Council in an
earlier approval by 23074DA (30) was RL2.8 as all floor levels shown on our
plan 06105-1 are above RL3.60 we certify that the floor levels for each
industrial unit as shown on plan 06105-1 will be above the estimated 1 in 100
year average recurrence interval design storm for a Q100 river flood.

\\Troy\jobs\Office Admin - Jobs\CT\06105 64 gateway drive\Info Request Response.doc

Used in these records

About this file

File size
5.5 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_0738 - Response to Information Request [As Published].pdf · 5.5 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.