Density index of not less than 65% according to as 1289.E6.1 where compaction test is in
accordance with AS1289.E5.1. Alternatively a satisfactory blow count of 7 or more per 300mm
when tested in situ with a penetrometer to AS1289.F3.3. may be used.

(b) CLAYS

Dry density ratio according to AS1289.E4.1 of not less than 95% where the compaction test is in
accordance with AS1289.E1.1. (standard) or 90% in accordance with AS1289.E2.1 (modified).

Clay fill should be moist to allow compaction and reduce subsequent movement.
5.00 NOTES - SITE MANAGEMENT
5.01 SOIL MOISTURE VARIATION IN SUB SOILS

Differential moisture under a structure due to extremes of wetting or drying is the major cause of
movement in clay sites.

To ensure the natural moisture content of the soil remains reasonably stable, gardens, trees,
shrubs, hose points, and septic tanks should not be located within 3m of the residence.

All downpipes should either be discharged directly into the street stormwater system via
underground drainage or to spitters discharging a minimum of 3m away from footings..

Our recommended drainage requirements for residential construction are shown on Appendix A
attached hereto.

Reference should also be made to the "Guide to Home Owners on Foundation Maintenance and
Footing Performance" published by the C.S.ILR.O which forms part of this report.

5.02 NON STRUCTURAL DISTRESS

There are many factors that affect the performance of a structure. The two (2) most commonly
occurring forms of house distress resulting from non-structural causes which are.

1. Direct tension slab cracking due to concrete shrinkage.
2. Growth cracking of brickwork.

Concrete shrinkage is resisted by the restraint imposed by the beam embedment into the soil and
the steel reinforcement.

Civil & Structural + Design & Drafting « Residential ¢ Commercial ¢ Subdivisions

John Titmus Consulting Engineers Pty Ltd ACN 083 070 651 as trustee of the
JTC Consulting Engineers Trust ABN 34 832 895 535 trading as JTC Consulting Engineers

Used in these records

About this file

File size
5.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

08_0066 - Operational Works - Landscaping, Drainage Works & Stormwater [As Published].pdf · 5.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.