The normal structural arrangement is that the inner leaf.of brick-
work in the external wails and at least some of the internal walls
(depending on the roof type) comprise the load-bearing structure-on
which any upper floors, ceilings and the roof are supported. In these
cases, it is internally visible cracking that should be the main focus
of attention, however there are a few examples of dwellings whose
external leaf of masonry plays some supporting role, so this should
be checked if there-is any‘doubt. In arly case, externally visible
cracking is important ag a guide to stresses on the structure generally,
and it should also be remembered that the external walls must be
capable of supporting themselves. _ os : .

Effects on framed structitres .

‘Timber or ste! framed buildings are less Ukely to exhibit cracking
due to sweli/shrink than masonry buildings because of their
flexibility. Also, the doming/dishing effects tend to'be lower because
‘of the lighter weight of walls. The main risks to framed buildings are
encountered because of the isolated pier footings used’ under walls.
Where erosion er saturation cause a footing to fall away, this can
double the span which’a wall must bridge. This additional stress can
create cracking in wall Unings, Particularly where there isa weak
point in the structure caused by a door or window opening. It ts,
however, unlikely that framed structures will be so stressed as to suffer
serious damage without first exhibiting some or all of the dbove
symptoms for a considerable period. The same warning period should
apply in the case of upheaval. It should ‘be noted, however, that where
framed buildings are supported by strip footings:there is only one leaf

‘of brickwork and thérefore the externally Visible walls are the *

supporting ‘structure for the building. In this case, the subfloor
masonry walls can be expected to behave as full brickwork walls. -

Effects on brick veneer structures :

Because the load-bearing structure of a brick veneer building is the
frame that makes up the interior leaf of the external walls plus
perhaps the interna! walls, depending on the type of roof, the
building can be expected to behave as a framed structure, except that
the external masonry will behave in a similar way to the external leaf:
of a full masonry structure, , oo ,

 

: Water Service and Drainage

 

Where a, water service pipe, a sewer or stormwater drainage pipe is in
the vicinity of a building, a water leak can cause erosion, swelling or
saturation of susceptible soil. Even a minuscule leak can be enough
to saturate a clay foundation, A leaking tap near a building can have
‘the same effect. In addition, trenches containing pipes can become.
watercourses even though backfilled, particularly where broken .
tubble jis used as fill. Water that runs along these trenches can be

and saturation,

Pipe leakage and trench water flows also encourage tree and shrub
- Foots'to the source of ‘water, complicating and exacerbating the
problem. . sO
‘cor roof plumbing can result in large volumes of rainwater being
‘oncentrated in a small area-of soil: . . .

_* Incorrect falls in roof guttering may result in overflows, as may
‘gutters-blocked with leaves etc, ~ -

responsible for serious erosion, interstrata seepage into subfloor areas -

*, Corroded guttering or downpipes can spill water to ground.

* Downpipes not positively connected to. a proper stormwater
collection system will direct a concentration of water to soil that is
directly adjacent to footings, sometimes causing large-scale
problems such as erosion, saturation and migration of water under
the building. , .

isness of Cracking

   

 

In general, most cracking found in masonry walls is a cosmetic
nuisance only and can be kept in repair or even ignored, The table
below is-a reproduction of Table C1 of AS 2870. .

AS 2870 also publishes figures relating to cracking in concrete floors,
however because wall cracking will usually reach the critical point -
significantly earlier than cracking in slabs, this table ts not
Teproduced here.. Lt . :

 

i Prevention/Cure

Plumbing :

Where building movement is caused by water service, roof plumbing,
sewer or stormwater failure, the remedy is to repair the‘problem.

It is prudent, however, ta consider also rerouting pipes away from
the building where possible, and relocating taps to positions where
any leakage will not direct water to the building vicinity. Even where
gully traps are present, there is sometimes sufficient sp!'to create .
erosion or saturation, particularly in moder installations using
‘smaller diameter PVC fixtures. Indeed, some gully traps are not
situated directly under the taps that are installed to charge thém,
with the result that water from the'tap may enter the backfilled
trench that houses'the sewer piping. If the trench has been poorly
backfilled, the water will either pond or flow along the bottom of

* the trench. As these trenches usually run alongside the footings and

can be at a similar depth, it is-not hard to see how any water that is
thus directed into a trench can easily affect the foundation's ability to
support footings or even gain entry to the subfloor area. :

Ground drainage’ :

In ail soils there is the.capacity for water to travel on the surface and
below it. Surface water flows can be established by inspection during
and after heavy or prolonged rain, If necessary, a grated drain system _
connected to the stormwater collection system is usually-an easy -
solution, | : 2 . : : -

It ts, however, sometimes necessary when attempting to prevent °
water migration that testing be carried. out to establish watertable .
‘height and subsoil water flows, This subject is referred to in BTF 19
and may properly be regarded ‘as an area for an expert consultant.

Protection of the building perimeter .

It-is essential to remember that the soil that affects footings extends
well beyond the actual building line. Watering of garden plants;
shrubs and trees causes somie of the most serious water problems. -

For this reason, particularly where problems exist or are likely to
occur, it is recommended that an apron of Paving be installed
around as much of the buliding perimeter as necessary, This’ paving

 

CLASSIFICATION OF DAMAGE WITH REFERENCE TO WALLS

 

 

 

 

 

Weathertightness often impaired

‘Description of typical damage and ‘required repair Approximate crack width . Damage
, : limit (see Note 3) oo, category
Hairline cracks * <0.1 mm 0
Fine cracks which do not need repair . <i mm 1
Cracks noticeable but easily filled. Doors and windows stick slightly <mm . 2
Cracks can be repaired and possibly a small amount of wall will need

to be replaced. Doors and windows stick. Service Pipes can fracture. -

5-15 mm (or a number of cracks . 3
- 3 rim or more in one group) :

 

15-25 mm but also depend |

Extensive repair work involving breaking-out and replacing sections of walls,
especially over doors and windows. Window and door frames distort. Walls lean

on number of cracks
or bulge noticeably, some loss of bearing in beams, Service pipes disrupted . .

 

 

 

 

 

 

re

Used in these records

About this file

File size
5.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

08_0066 - Operational Works - Landscaping, Drainage Works & Stormwater [As Published].pdf · 5.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.