| * Water that ig transmitted into masonry, metal or timber building
elements causes damage and/or decay to thosé elements. .
+ High subfloor humidity and moisture content create an ideal
" environment for various pests, including termites and spiders.

- . * Where high moisture levels are transmitted to the flooring and
walls, an increase in the dust mite count can ensue within the
living areas. Dust mites, as well'as dampness in general, can be a
health hazard to inhabitants, particularly those who are .

. abnormally susceptible to respiratory ailments.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The garden :
: as Joe . The deal vegetation layout is to have lawn or plants that require
HUTTE vo only light watering immediately adjacent to the drainage or paving
Patis [1 i fe L. edge, then more demanding plants, shrubs and ‘trees spread out in
Si oo oy that order. : :

Overwatering due to misuse of automatic watering systems is a

common cause of saturation and water migration under footings. If
‘it is necessary to use these systems, it is important to remove garden . -
" beds to a completely safe distance from buildings. .

Existing trees

Where a tree is causing a problem of soil drying or there is the

existence or threat of-upheaval of footings, if the offending roots are
- subsidiary and their removal will not significantly damage the tree,
they should be severed and a concrete or metal barrier placed
vertically in the soil to prevent future root growth in the direction of
the building. If it is not possible to remove the-relevant roots
without damage to the tree, an application to.remove the tree should
be made-to the local authority. A prudent plan is to transplant likely
offenders before they become a problemi... moe

 

 

  
 

 

 

 

 

 

 

 

 

 

 

Information on trees, plants and shrubs °

State departments overseeing agriculture can give information

- Tegarding root patterns; volume of water needed and safe distance
from buildings of most species.- Botanic gardens are also sources of
information. For information on plant roots and drains, see Building
Technology File 17. 2 - :

 

 

should extend outwards a minimum of 900 mm (more in highly Excavation 7
reactive soil) and should have a minimum fall -away from the" Excavation around footings must be properly engineered. Soil
building of 1:60. The finished paving should be no jess than 100 - Supporting footings can only be safely excavated at an.angle that
mm below brick vent bases.  - - allows the soil under the footing:to remain stable. This angle is

: called the angle of repose (or friction) and Varies significantly
Tt is prudent to relocate drainage pipes away from this-paving, if between soil types and conditions. Removal of soil within the angle

possible, to avoid complications from future Jeakage. If this is not i
practical, earthenware pipes should be replaced by PVC and ~ of repose will cause subsidence.
backfilling should be of the same soil type as the surrounding soil : ’
-and compacted, to the same density. : :

Except in areas where freezing of water is an issue, it is wise to-. so Co : . :
remove taps in the building area and relocate them well away from Where erosion has occurred that has washed away soil adjacent to

‘iRemediation

the building — preferably not uphill from it (see BTF 19), . > footings, soil of the same classification should be introduced and
ot : wo, . compacted same di . Whi have been.
Tt-may be desirable to install a grated drain at the outside edge of the ‘ - od cucemenon other sn cone ok may be required
paving on the uphill side of the building. If subsoil drainage is . 4 , , .
sded thi be led und J Remediation of footings and foundations is generally the realm of a
eo this can be installed under the surface drain. t jalist consultant. /

Condensation . se " Where isolated footings rise and fall because of swell/shrink effect,
In buildings with a subfloor void such as where bearers and joists the homeowner may be tempted to alleviate floor bounce by filling

support flooring, insufficient ventilation creates ideal conditions for the gap that has appeared between the bearer and the pier with .
condensation, particularly where there is little clearance between the blocking. The danger here is that when the-next swell segment of the
floor and the ground. Condensation adds to the moisture already eycle occurs, the extra blocking will push the floor up into an
present in. the subfloor and significantly slows the process of drying __ 8ccentuated dome and may also cause loca) shear failure in the soll.
out, Installation of an adequate subficor ventilation system, either “IE it 4s necessary to.use blocking, it should be by a pair of fine

natural or mechanical, is desirable. - . __-Wedges and monitoring should be carried out fortriightly.
- Warning: Aithough this Building Technology File deals with . This BTF was prepared by John Lewer FAIB, MIAMA, Partner,
cracking in buildings, it should, be said that subfloor moisture can ‘Construction Diagnosis. . :

result in the development of other problems, notably:

 

   

The information in this and other issues in series was derived from various sources and believed to be correct when published.

  
 
  

 

advisory. It is provided in good faith and not claimed to be an

     

 

needs to be obtained before tal

 
 

‘Furthér professional advice

    

: Distributed by oo
CSIRO PUBLISHING PO Box 1139, Collingwood 3066, Australia
Freecall 1800 645 051 Te! (03) 9662 7666 Fax (03) S662 7555 www.publish.csiro.au

. Email: [email protected] ; .
© CSIRO 2003. Unauthorised copying of this Building Technology file is prohibited ,

Used in these records

About this file

File size
5.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

08_0066 - Operational Works - Landscaping, Drainage Works & Stormwater [As Published].pdf · 5.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.