115. The development shall be provided with approved permanent signage that is
deigned in accordance with Noosa’s Look and Feel document to educate the
public on the function of the bioretention basin. The wording for the signage for
each bioretention basin is to include: “BIORETENTION BASIN - This bioretention
basin reduces the pollution of our waterways by reducing the amount of heavy
metals, litter, suspended solids, and nutrients discharged to Lake Doonella”.
FOLLOWING CONSTRUCTION / PRIOR TO THE ON-MAINTENANCE INSPECTION
Certification
116. Upon completion of the work a certificate must be issued by an RPEQ certifying
that the works have been constructed in accordance with the Operational Works
permit.
117. A condition report of the drainage system must be completed for agreement prior
to requesting the works to be accepted On-Maintenance. The condition report is
to include a CCTV inspection of the existing pipe and must include at least 50m
upstream and downstream of all works.
As Constructed Plans and ADAC XML Files (Council)
118. Prior to acceptance of civil works to become Council assets “On Maintenance”,
satisfactory “As-Constructed” records must be submitted to Council. The bundle
of “As Constructed” information must include:
v. As-Constructed Engineering Drawings. Data is to be submitted in an
electronic drawing file format (.dwg), with all plans clearly endorsed “As-
Constructed”, along with the accompanying hardcopies (PDFs of the As-
Constructed .dwg drawing files), and;
c. ADAC XML Digital File. ADAC File format (ADAC - Asset Design As
Constructed) prepared in accordance with industry standards and recorded
in “MGA - UTM56 / GDA94” projection.
d. Please Note: Further information and advice relating to the as-constructed
drawing presentation, as-constructed survey capture and associated
guidelines for preparation of a compliant ADAC XML digital file are available
on the webpage titled “As-Constructed Guidelines” and accessible at the
Noosa Council Website: Planning & Development / Development Tools &
Guidelines / As-Constructed Guidelines.
e. The “As-Constructed” drawings will require certification by a:
i. Qualified experienced Civil Engineer (RPEQ) confirming design
intent and conformance with applicable standards and
specifications, along with the relevant descriptions of assets,
services and structures and;
ii. Licensed Surveyor in regard to the cadastral and locational
information, levels and applicable survey datum.
f. The data must be in accordance with Council’s “Planning Scheme Policy 6
– Engineering Design Standards”, and fully detail the levels for all
engineering works including but not limited to the drainage network and
structures, finished ground and pavement surface levels.