Original source · versioned page text
Attachment K - HSTP Design
Very large file (11.6 MB): the original may take a few minutes to open or download. The page text below is quick to read.
The system shall have the ability to isolate the effluent from the sprinkler system to enable servicing and maintenance requirements of the irrigation area. The method of isolation cannot cause harm to the treatment plant operation (pump, electrical, treatment). Manufacturer of the treatment plant is to approve the method of isolation. Spray outlets are not permitted to operate when persons are required to enter the Land Application Area (e.g. when being serviced and/or maintained). There are obvious increased public health risks associated with effluent spray irrigation systems due to the potential contact with effluent by humans, animals and insects. 5.3 Planting Regime. Plantings improve the efficiency of the system with the uptake of nutrient and natural transpiration processes. Further qualified advice from local nurserymen and the local regulatory authority should be preferred when choosing plants that may be more or less suitable or acceptable to your region. Grasses should be kept well mown and raked for better evaporative and transpiration processes (avoid throwing grass clippings onto the Land Application Area). Shrubs should be kept well pruned for better evaporative and transpiration processes. Endemic vegetation must be retained and/or reinstated. Following the site preparation, installation and pre-commissioning tests the Land Application Area shall be allowed to revegetate with sufficient appropriate shallow rooting grasses or shrubs, as determined by historical performance outcomes. Unearthed Geotechnical P/L recommends further assessment regarding planting requirements be sought prior to, or at the time of installation of the Land Application Facility. It may be necessary to implement an additional planting regime. Do not plant shrubs or trees within the surface water diversion drains, as these drains need to be kept free of obstruction and debris for maximum diversion efficiency. We recommend the application of dolomite at a nominal rate (say, 0.25 kg/sqm) when preparing the existing soil. This will assist with both plant growth and/or pH control. Further applications will be required during the serviceable life of the Land Application Area. Unearthed Geotechnical P/L. 10 Design Report 023-038
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.