MCU14/0056 - Town Planning Report
town planning
report
Business Uses Code
Specific Outcomes Acceptable solutions (if self-assessable) Probable Compliance
solutions (if code assessable)
O7 Outdoor dining areas are designed and located so S7.1 Walls to outdoor dining areas are— Outdoor dining associated with the food premises is
that— a) if facing a roadway or other public area, transparent; proposed. These areas will not be fully enclosed.
a) structures are aesthetically pleasing and in keeping b) not made of flexible, roll-up or drop plastic sheeting;
with the existing character of the area, including the c) separated from the floor and any roof by a minimum vertical gap
architecture of the associated building; of 500mm; and
b) outdoor dining adds to the landscaped streetscape d) if detachable or collapsible, are only used during inclement
without increasing perceived building bulk; weather; AND
c) temporary walls or roofs are stored when not in use
S7.2 Roof, walls or other structures do not extend beyond the Complies – buildings will be wholly contained within
and secured at all times; the boundaries of the site
boundaries of the premises; AND
d) adequate air movement is available; and
e) structures do not impede the movement of S7.3 The outdoor dining area complies with Planning Scheme Policy Will comply
pedestrians or vehicles; AND PSP14 Outdoor Dining.
O8 Adequate clearways and head clearance are provided S8.1 Roof structures over outdoor dining areas have a minimum Complies
to allow safe movement of users of the premises. clearance height of 2.1m.
Car Parking S9.1 Off street carparking is provided at a rate of 1 space per 20m2 of Refer to attached Traffic Report. Based on provisions
O9 Sufficient carparking is available to accommodate the gross floor area; within the planning scheme 153 car spaces are
number and type of vehicles likely to be generated by required. 224 car spaces are provided, well in excess of
the Council’s requirements.
the uses on the site
14.16 Effects of use
Electricity infrastructure S18.1 No solution provided Complies – the proposed development does not
O18 The development does not adversely impact on adversely impact on existing or future electricity supply
existing or future electricity supply infrastructure; AND infrastructure.
O19 All uses and works maintain an adequate safe S19.1 Development for uses adjacent to or within 50m of an existing Site is not within 50m of an existing electricity
distance from electrical infrastructure including electricity substation incorporates noise attenuation measures to substation.
saunders havill group page 49 Job 6520
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.