                                                                                                                                                                                                                                                                                                                                               GENERAL NOTES
                                                                                                                                                  1500                                                                                                                                                                                          1. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL OTHER CONSULTANTS
                                                                                                                                                                                                                                                                                                                                                DRAWINGS AND SPECIFICATIONS. 2. BEFORE PROCEEDING WITH THE WORK ANY DISCREPANCIES




                                                                                                                                   1500
                                                                                                                                                                                                                                                                                                                                                IN THE CONTRACT DOCUMENTS SHALL BE REFERRED FOR DECISION TO THE ENGINEER.




                                                                                                                            3000
                                                                                                                                                                                                                                                                                                                                                3. DO NOT SCALE FROM DRAWINGS IF IN DOUBT, ASK!!
                                                                                                                                                                                           PROPOSED 100MM UPVC SEWER LINE 23930MM                                                                                                               4. CONTRACTOR SHALL VERIFY ALL LOCATIONS OF SERVICES, ALL DIMENSIONS AND LEVELS
                                                                                                                                                                                                                                                                                                                                                5. ALL MATERIALS & WORKMANSHIP SHALL BE IN ACCORDANCE WITH AS2890, THE (INCLUDING
                                                                                                                                                                                                                                       UNITY WATER ASSET                                                                                        THE QUEENSLAND SUPPLEMENT), THE QUEENSLAND BUILDING ACT AMENDMENT ACT 1991 AND
                                                                                                                                                                       PROPOSED MANHOLE                                                                                                                                                         6. THE CONTRACTOR IS RESPONSIBLE TO OBTAIN RELEVANT APPROVALS PRIOR TO
                                                                                                                                                                                                                                       MANHOLE 1050                                                                                             7. ALL STORMWATER CULVERTS TO BE RCP CLASS 2. ALL ROOFWATER PIPES TO BE uPVC
                                                                                                                          EXISTING BLOCKWORK                           MANHOLE 1050                                                    ASSET ID - 2663533                                                                                       8. SILT MANAGEMENT PLAN TO REMAIN IN PLACE UNTIL COMPLETION OF WORKS AND
                                                                                                                          RETAINING WALL 1M                            ASSET ID - TBA                                                  S.L - 11.17                                                                                              9. ALL PROPOSED OPERATIONAL WORKS SHALL BE CONSTRUCTED IN ACCORDANCE WITH                                                                                                                                                                                   LINDSAY CONSULTING PTY LTD




                                                                                                                          APPROX THROUGHOUT                            S.L - 14.00                                                     I.L - 8.56                                                                                               COUNCIL'S OPERATIONAL WORKS APPROVAL LETTER AND COUNCIL'S DECISION
                                                                                                                                                                                                                                                                           SEWER EASEMENT                                                                                                                                                                                                                                                                                                                 LINDSAY CONSULTING PTY
                                                                                                                                                                       I.L - 8.56                                                                                                                                                               10.CONCRETE KERB RAMPS SHALL BE ALIGNED TO COMPLY WITH COUNCIL'S STANDARD                                                                                                                                                                                                    LTD
                                                                                                                                                                       PROPOSED HCB TO ALLOW                                                                                                                                                    DRAWING AND SHALL BE CONSTRUCTED STRICTLY IN ACCORDANCE WITH COUNCIL STANDARD
                                                                                                                                                                       FOR 1% MIN GRADE FROM                                                                                                                                                    11. ALL TEMPORARY AND PERMANENT ROAD SIGNS AND LINEMARKING SHALL COMPLY WITH
                                                                                                                                                                                                                                                                                                                                                THE CURRENT MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES(M.U.T.C.D.). EXISTING LINE
                                                                                                                                                                       INTERNAL SEWER LINE.                                                                                                                                                                                                                                                                                                                                                                                                                                                                   RPEQ 4928
                                                                                                                                                                                                                                                                                                                                                MARKING SHALL BE REMOVED BY GRINDING NOT"BLACKING OUT". COUNCIL DOES NOT
                                                            DRIVEWAY                                                                                                   ESTIMATED IL - 13.184                                                                                                                                                    APPROVE OF BLACKING OUT OF EXISTING LINE MARKING. KERB MARKERS SHALL BE PROVIDED                                                                                                                                                                          OFF. 2C/82 PARKER STREET, MAROOCHYDORE            PH 54 792 118
                                                                                                                                                                                                                                                                                                                                                FOR ALL WATER, TELSTRA AND ANY OTHER SERVICE CONDUIT ROAD CROSSINGS AS
                                                                                                                                                                                                                                                                                                                                                APPLICABLE.                                                                                                                                                                                                                                              THIS DRAWING REMAINS THE PROPERTY OF
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         LINDSAY CONSULTING PTY LTD AND IS FOR
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           THE SOLE USE OF THE CLIENT. NO PART
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         MAY BE USED IN PART OR WHOLE WITHOUT
                      EXISTING INDUSTRIAL SHED
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            PRIOR EXPRESS WRITTEN CONSENT OF
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               LINDSAY CONSULTING PTY LTD
                                                                                                                                                                                                                                                                                                                                              STORMWATER DRAINAGE NOTES
                                                                                                                                                                                                                                                                                                                                               1.ANY CHANGES SHALL BE APPROVED BY THE ENGINEER IN WRITING PRIOR TO CARRYING OUT
                                                                                                                                                                                                                                                                                                                                               OF THE WORKS
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        CLIENT AND PROJECT DESCRIPTION
                                                                                                                                                                               EXISTING SEWER
                                                                                                                                                                                                                                                                                                                                               2.ALL LEVELS TO AHD.
                                                                                                                                                                                                                                                                                                                                               3.ALL DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.
                                                                                                                                                                                                                                                                                                                                               4.ALL DIMENSIONS AND LEVELS ARE TO BE CHECKED ON-SITE BEFORE WORK COMMENCES.
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           GE & LK GRAMS
                                                                                                                                                                               LINE FROM INDUSTRIAL
                                                                                                                                                                               SHEDS TO MANHOLE.
                                                                                                                                                                               LINE TO BE DISCONTINED/
                                                                                                                                                                                                                                                                                                                                               5. DIMENSIONS SHALL NOT BE OBTAINED BY SCALING THE DRAWING.
                                                                                                                                                                                                                                                                                                                                               6. FOR BUILDING SET-OUT REFER ARCHITECTURAL DRAWINGS                                                                                                                                                                                                        PROPOSED SUBDIVISION
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           53-57 RENE ST
                                                                                                                                                                                                                                                                                                                                               7. THE LOCATION AND DEPTH OF ALL SERVICES SHALL BE VERIFIED ON SITE WITH THE
                                                                                                                                                                               MADE REDUNDANT                                                                                                                                                  REVLEVANT AUTHORITY PRIOR TO THE COMMENCEMENT OF WORKS
                                                                                                                                                                               1500 SHORT OF PROPOSED                                                                                                                                          8. DURING CONSTRUCTION BARRIERS, LIGHTS & SIGNS SHALL BE MAINTAINED TO ENSURE SAFE


                                                            DRIVEWAY
                                                                                                                                                                               BOUNDARY AND DIRECTED
                                                                                                                                                                               TO PROPOSED HCB
                                                                                                                                                                                                                                                                                                                                               PASSAGE OF TRAFFIC AND PEDESTRIANS IN ACCORDANCE WITH THE REQUIREMENTS OF THE
                                                                                                                                                                                                                                                                                                                                               LOCAL AUTHORITY.
                                                                                                                                                                                                                                                                                                                                               9.ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH CURRENT LOCAL AUTHORITIES
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           NOOSAVILLE
                                                                                                                                                                                                                                                                                                                                               SPECIFICATIONS AND STANDARDS.
                                                                                                                                                                                                                                                                                                                                               10.THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING ALL RELEVANT AUTHORITIES
                                                                                                                                                                                                                                                                                                                                               AND PAYING ALL FEES NECESSARY BEFORE COMMENCING WORK, FOR LOCATING ALL EXISTING
                                                                                                                                                                                                                                                                                                                                               SERVICES AND FOR REPAIR OF ANY SERVICES DAMAGED AS A RESULT OF THE FOOTPATHS
                                                                                                                                                                                                                                                                                                                                               AND PRIVATE PROPERTY SHALL BE REINSTATED TO THEIR ORIGINAL CONDITION.
                                                                                                                                                                                                                                                                                                                                               11.ANY OBSOLETE/REDUNANT DRIVEWAY CROSSINGS AND DRAINAGE OUTLETS FROM THE
                                                                                                                                                                                                                                                                                                                                               KERB AND CHANNEL INCLUDING ASSOCIATED PIPES ACROSS THE FOOTPATH SHALL BE                                                                                                                                                                                 DRAWING TITLE
                                                                                                                         EXISTING BLOCKWORK                                                                                                                                                                                                    REMOVED AND THE KERB AND CHANNEL AND FOOTPATH REINSTATED TO THE LOCAL
                                                                                                                         RETAINING WALL 1M                                                                                                                                                                                                     AUTHORITIES CURRENT SPECIFICATIONS AND OR STANDARDS
                                                                                                                                                                                                                                                                                                                                               12.THE CONTRACTOR'S ATTENTION IS DRAWN TO THE REQUIREMENTS OF THE WORKPLACE
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           OPERATIONAL WORKS
                                                                                                                         APPROX THROUGHOUT
                                                                                                                                                                                                                                                                                                                                               HEALTH AND SAFETY ACT 1995. ALL WORK IS TO BE CARRIED OUT IN ACCORDANCE WITH THIS
                                                                                                                                                                                                                                                                                                                                               ACT AND IN PARTICULAR THE CONTRACTOR TO ENSURE THE REQUIREMENTS OF THIS
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           WATER AND SEWER
                                                                                                                                                                                                                                                                                                                                               SPECIFICATION WITH REGARD TO 'NOTIFICATION IN RELATION TO A NOTIFIABLE PROJECT ARE
                                                                                                                                                                                                                                                                                                                                               FULFILLED.




                                                                                                                                                                               1
                                                                                                                                                                                                                                                                                                                                               13.BENCHING OF PIT STRUCTURES SHALL HAVE A SMOOTH FINISHED SURFACE, AND PIPES




                                                                                                                                                                        2
                                                                                                                                                                                                                                                                                                                                               SHALL NOT PROJECT INSIDE THE SHAFT OF THE PIT.




                                                                                                                                                                     43
                      EXISTING INDUSTRIAL SHED                                                                                                                                                                                                                                                                                                 14.STORMWATER DRAINAGE PIPES SHALL BE UPVC PIPE (MINIMUM SEWER CLASS SN8) TO AS
                                                                                                                                                                                                                                                                                                                                               14. 1260 OR APPROVED EQUIVALENT. MINIMUM COVER TO ROOFWATER PIPES SHALL BE 50mm
                                                                                                                                                                                                                                                                                                                                               EXCEPT WHERE REDUCED COVER IS REQUIRED TO DISCHARGE TO THE KERB AND CHANNEL.
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        SCALES




                                                                                                                                                            0
                                                                                                                                                                                                                                                                                                                                               15.MINIMUM PIPE GRADES FOR STORMWATER AS 3500 PART 3: PIPES SHALL COMPLY WITH




                                                                                                                                                         P1
                                                                                                                                                                                                                                                                                                                                                           - 1.0% (MIN) GRADE FOR PIPES < 150 DIA.
                                                                                                                                                                                                                                                                                                                                                           - 0.5% (MIN) GRADE FOR PIPES > 150 BUT < 375 DIA.




                                                                                                                                                 nS                                                                                                                                                                                                                                                                                                                                                                                                                                                                                      A1 - 1:200
                                                                                                                                                                                                                                                                                                                                               16.CONCRETE DRIVEWAY AND PARKING AREAS SHALL BE CONSTRUCTED WITH 32 MPa
                                                           DRIVEWAY                                                                                                                                                                                                                                                                            17.REFER HYDRAULIC DRAWINGS FOR SANITARY DRAINAGE LAYOUTS.
                                                                                                                                                                                                                                                                                                                                               18.COMPACTION OF MATERIAL UNDER CONCRETE DRIVEWWAYS AND PARKING AREAS SHALL BE
                                                                                                                                                                                                                                                                                                                                                           (i) 75% MINIMUM DENSITY FOR COHESIONLESS MATERIAL (AS 1289 E5.1) AND
                                                                                                                           1o
                                                                                                                                                                                                                                                                                                                                                           (ii) 90% RELATIVE DRY DENSITY (STD COMP.) FOR MATERIAL OTHER THAN (i)
                                                                                                                T        28
                                                                                                             LO




                                                                                                                                                                                                                                                                                                                                                                                                                   Expansion joints:
                                                                                                                                                                                                                                                                                                                                                                                                        Types 1 and 2 at 16.0m centres
                                                                                                                                                                                                                                                                                                                                                                                                              Types 3 at 6.0m centres
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        SURVEY DATUM
                                                                                                                                                                                                                                                                                                                                                                                   Type 1. 10 thick, full depth closed cell cross linked
                                                                                                                                                                                                                                                                                                                                                                                                         polyethylene foam (85-150kg/m )



                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          .
                                                                                                                                                                                                                                                                                                                                                                                   Type 2. 10 thick compressed granulated cork board
                                                                                                                                                                                                                                                                                                                                                                                 Type 3. Connolly Key Joint with 100mm thick concrete
                                                                                                                                                                                                                                                                                                                                                                                          Installation to manufacturers' instructions                           B




                                                                                                                                                                                                                                                                                                                       MATCH EXISTING
                                         EXISTING CARPARK AND DRIVEWAY                                                                                                                                                                                                                                             C                                                                                                                                                                                                                             C
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        ASSOCIATED CONSULTANTS
                                                                                                                                                                                                                                                                                                                                                         Contraction joints at 2.0m centres:
                                                                                                                                                                                                                                                                                                                                                                                                                                                                B
                                                                                                                                                                                                                                                                                                                                                         25 deep x 6 wide recess, saw cut,                                         PLAN




                                                                                                                                                                                                                                                                                                                                                                                                     100 or as specified
                                                                                                                                                                                                                                                                                                                                                         or crack inducer 25 deep.




                                                                                                                                                                                                                                                                                                                                                                                                     refer note 5
                                                                                                                                                                                                                                                                                                                                                                                                                                                         F72 Fabric (CENTRAL)

                                                                                                                           EXISTING BLOCKWORK
                                                                                                                           RETAINING WALL 1M                                             PROPOSED BOUNDARY                                                                                                                                            Contraction joint                                                            Compacted sub-grade
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  Expansion Joint
                                                                                                                           APPROX THROUGHOUT                                                                                                                                                                                                                                                                               SECTION C - C
                                                                                                                                                                                                                                                                                                                                              1450
                                                                                                                                                                                                                                                                                                                                        TO BE CONFIRMED ON-SITE
                                                                                                                                                                                                                                                                                                                                                                          1200
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        -
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          APPROVED PLAN
                     EXISTING BLOCKWORK
                     RETAINING WALL REDUCING                                                                                                                                                                                                                                                                                                                                                                                FOOTPATH NOTES
                     TO APPROX 300MM                                                                                                                                                                                                                                                                                                                                                                                        1. Concrete N25 in accordance with AS 1379 and AS 3600.            6. Concrete footpaths, adjoining existing driveways are to be
                                                                                                                                                                                                                                                                                                                                                                                                                            2. All concrete to be broom finished.                                 transitioned over a minimum 5.0m length.


                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             RAL21/0028
                                                                                                                                                                                                                                                                                                                                                              SECTION B-B                                                   3. Contraction/expansion joints, 2m MAX spacing.                   7. A street opening permit must be obtained from Council, seek
                                                                                                                                                                                                                                                                                                                                                                                                                            4. Finished surface tolerance to be maximum +6mm -0mm     relative    approval of location and levels prior to excavation.
                                                                                                                                                                                                                                                                                                                                                                                                                               to kerb level and crossfall specified.                          8. All dimensions in millimetres.
                                                                                                                                                                                                                                                                                                                                                                                                                            5. Thickness to be increased to 125mm at residential vehicular


                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          NOOSA COUNCIL
                                                                         GRASS/LANDSCAPINGPROPOSED 600 X 600                                                                                                                                                                                                                                                                                                                   crossings. Reinforce with F72 MIN fabric, 50mm top and edge
                                                                                                                                                                                                                                                                                                                                                                                                                               cover. Provide a contraction or expansion joint at both ends

                                                                                                             STORMWATER PIT. ALL                                                                                                                                                                                                                                                                                               of thickened section.



                       GRASS/LANDSCAPING
                                                                                                             INTERAL STORMWATER
                                                                                                             TO BE DIRECTED TO                                                  225 UPVC- MIN GRADE 1%
                                                                                                                                                                                                                            - 24045 NOM.                            900X900 FEILD INLET
                                                                                                                                                                                                                                                                                                                                                                                                   FOOTPATH DETAIL - IF REQUIRED
                                                                                                                                                                                                                                                                                                                                                                                                                           Not to scale                                                                                                                                                                                                    25 MARCH 2022
                                                                                                             THIS PIT FOR DISCHARGE                                                                                                                                 ALL LEVELS TO BE
                                                                                                             TO COUNCIL NETWORK                                  1000                                                                                               CONFIRMED ONSITE
                                                                                                                                                                                                                                                                    (375mm discharge) TO
                                                                                                                                          1500




                                                                                                                                                                                                                                                                    BE RELOCATED AS SHOWN
                                                                                                                                                                                                                                                              750




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        DANLEY KEY JOINT WITH                                                  20 X 40 JOINT SEALANT
                                                                                                                                                                                                                     DRIVEWAY CROSSOVER TO
                                                                                                                                                 750




                                                                                                                                                       1500
                                                                                                                                                                                                                     COMPLY WITH RS-051                                       STORMWATER EASEMENT                                                                                                                                                                                                       R12 DOWELS AT 300CRS

                                                                                       Provide 1 No 40mm                                                                                                                                                      EXISTING 150MM
                                                                                       Water Meter in accordance                                                                                                                                              WATERMAIN -                                                                                                                                                                                                                                                                          TYPICAL KEY JOINT
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           Not to scale
                                                                                       with drawings SCW350, 355 and                                                                                                                                          ASSET ID - 203369                                                                                                                                                                                                                                         CUT EVERY SECOND WIRE DIRECTLY
                                                                                                                                                                                                                                6000
                                                                                       360                                                                                                                                                                                                                                                                                                                                                                                                                              UNDER JOINT AND DEPRESS FABRIC LOCALLY
                                                                                                          EXTEND EXISTING 150MM                                                                                                                                                                VEGETATION            PROTECTION NOTES                                                                                                                                                                                                                                                                   REVISION LIST
                                                                                                          WATER MAIN TO SERVICE                                                                                                                                                                1. TREES LOCATED ALONG THE FOOTPATH SHALL BE, TRANSPLANTED PRIORTO                                                                                                                                                                                                                                       A ORIGINAL ISSUE                                         11/02/22
                                                                                                                                                                                                                                                                                               CONSTRUCTION, OR REPLACED IF DESTROYED.
                                                                                                          PROPOSED WATER METER                                                                                                                                                                                                                                                                                                                                                                                                                            SAW CUT - (SC)
                                                                                                                                                                                                                                                                                               2. WHEN WORKING WITHIN 4m OF TREES, RUBBER OR HARDWOOD GIRDLES SHALL BE
                                                                                                          FOR EXISTING INDUSTRIAL                                                                                                                                                              CONSTRUCTED WITH 1.8m BATTENS CLOSELY SPACED AND ARRANGED VERTICALLY FROM
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                Not to Scale

                                                                                                                                                                                                                                             LOCATION OF DRIVEWAY CROSSOVER                                                                                                                                                                                                                                                  SAW CUTS (USING A SOFT CUT SAW)
                                                                                                          SHEDS                                                                                                                                                                                GROUND LEVEL. GIRDLES SHALL BE STRAPPED TO TREES PRIOR TO CONSTRUCTION AND                                                                                                                                                    SHALL BE INSTALLED WITHING 8HRS
                                                                                                                           EXISTING 40MM WATER                                                                                               SHOWN FOR APPROVAL PURPOSES TO                                                                                                                                                                                                                                                  OF CONCRETE PLACEMENT. WHERE AMBIENT
                                                                                                                                                                                                                                                                                               REMAIN UNTIL COMPLETION.                                                                                                                                                                                                      TEMP IS GREATER THAN 32 DEGREES
                                                                                                         33498             METER CURRENTLY BEING                                                                                             A CODE COMPLIANT DRIVEWAY IS POSSIBLE.            3. TREE ROOTS SHALL BE TUNNELLED UNDER, RATHER THAN SEVERED. IF ROOTS ARE                                                                                                                                                     THIS TIME SHALL BE REDUCED TO 4 HOURS
                                                                                                                           USED BY EXISTING                                                                                                  PROPOSED LOT DEVELOPER REQUIRED                   SEVERED THE DAMAGED AREA SHALL BE TREATED WITH A SUITABLE FUNGICIDE. CONTACT                                                                                                                                                                                                    SL82 FABRIC (CENTRAL)
                                                                                                                           INDUSTRIAL SHEDS. TO BE                                                                                           TO PROVIDE COUNCIL WITH DRIVEWAY                  RELEVANT COUNCIL ARBORIST FOR FURTHER ADVICE.
                                                                                                                           DISCONNECTED FROM                                                                                                 CROSSOVER LOCATION                                4. ANY TREE LOPPING REQUIRED SHOULD BE UNDERTAKEN BY AN APPROVED ARBORIST.
                                                                                        OPERATIONAL WORKS                  SHEDS AND MADE
                                                                                                                           AVAILABLE TO PROPOSED                                                                                                                                                                                                                                                                                                                                                                                                      PAVEMENT DESIGN
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                Not to Scale
                                                                                                                           LOT




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              150
                                                                                                   Protect   your




                     KEY JOINT
                                                                                                   PERSONAL

                                                                                                   INTERESTS.


                                                                                                     HEAD


                     SAW JOINT
                                                                                                   EYES
                                                                                                   EARS
                                                                                                              BODY
                                                                                                                                                              It is the responsibility of the                  All proposed operational works shall be constructed
                                                                                                                     NOTE                                     Foreman to contact the
                                                                                           HANDS
                                                                                                                     THE ENGINEER MUST BE NOTIFIED OF         relevant service authorities to                  in accordance with Council's Operational Works approval                                                                                                                                                                                                                                                                                                                                 Computer File
                     PROPOSED EASEMENT                                                         FEET
                                                                                                                     CHANGES PLANS. IF NOT, AS
                                                                                                                     CONSTRUCTED DRAWINGS WILL NOT BE
                                                                                                                     ISSUED
                                                                                                                                                              ascertain the exact location of
                                                                                                                                                              services prior to construction.
                                                                                                                                                                                                               letter and Council's Decision Notice - Development Permit.                                                                                                                                                                                                                                           PAVEMENT DETAILS - CONCRETE SURFACE
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       Not to scale
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         031159CP.DWG
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       DRAWING NUMBER                                         SHEET   REV.

                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          03-1159-C1            1 A
Document Set ID: 21825014
Version: 1, Version Date: 17/02/2022
Log in to download the original file

Approved Plans - RAL21-0028.pdf · 3.4 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.