Skip to the record
Mmm.. taste the original NoosaWatch™

Original source · versioned page text

Amended Architecturals

of 13

Page text shows just the words. Original shows the document exactly as it was published.

Very large file: it may take a few minutes

The original of this document is very large (13.2 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

        COOROY MOUNTAIN HOUSE
          GENERAL NOTES
                                                                                                                                                                        ARCHITECTURAL DRAWINGS
        * DO NOT SCALE DRAWINGS Larger scale drawings take precedence over smaller scale drawings. Noted dimensions take precedence over
          scale. IF IN DOUBT, REFER TO OWNER.
                                                                                                                                                                SHEET                         NAME
        * These drawings are to be read in conjunction with written specifications, all relevant consultants' drawings and other written instructions issued
          during the course of the contract.                                                                                                                     A000     TITLE PAGE AND NOTES
        * REPORT DISCREPANCIES, errors or ambiguities found in the drawings to the OWNER immediately for correction and/or direction.
          All workmanship & materials are to be in accordance with the current Building Code of Australia, relevant Australian Standards including               A001     NOTES AND LEGENDS
          amendments and the requirements of Council and other authorities having jurisdiction.                                                                  A102     OVERALL SITE PLAN
        * Install materials, fixtures and fittings in accordance with manufacturers' specifications and recommendations and the requirements of                  A103     SITE PLAN (PARTIAL)
          manufacturers' warranties.
        * THE BUILDER SHALL VERIFY all locations, dimensions, levels, inverts, distances and features on site prior to commencement of any work or               A300     GROUND FLOOR PLAN
          the production of any shop drawings. Should existing conditions differ from those shown or indicated or if it appears that the contract                A380     ROOF PLAN
          documents do not adequately detail the work to be done, the Builder must notify the OWNER prior to continuing with related work. No
          allowance will be made on behalf of the Builder for extra expenses resulting from the Builder's failure or neglect in determining the conditions       A500     ELEVATIONS
          under which the work is to be performed.                                                                                                               A501     ELEVATIONS
        * DO NOT WELD, GRIND, TORCH or otherwise generate sparks or open flames WHEN FLAMMABLE MATERIALS ARE IN CLOSE                                            A700     DOOR & WINDOW SCHEDULE
          PROXIMITY to the work area. When conducting such work, maintain fire extinguishers and/or working hoses within easy reach at all times.
        * DO NOT SMOKE ON SITE                                                                                                                                   A901     PERSPECTIVES
        * MAINTAIN THE SITE in an ordered and clean manner. Sweep and remove rubbish as work progresses and at minimum daily intervals.                          A902     PERSPECTIVES
          Subcontractors are to remove rubbish produced by their part of the work at minimum daily intervals and when complete.
        * RECYCLE waste materials which display the universal recycling symbol as well as paper, cardboard, glass bottles and other suitable materials
                                                                                                                                                                 A903     PERSPECTIVES
          as advised by the waste management operator. Separate recyclable items from non-recyclable items during clean-up. Maintain clearly marked              A904     PERSPECTIVES
          bins / skips on site to facilitate this.
        * NO TIMBERS FROM RAINFORESTS, OLD GROWTH FORESTS NOR OTHER SENSITIVE ECOSYSTEMS MAY ENTER THE SITE or be
          used to build sub-assemblies off-site. Timbers used temporarily or permanently in the course of the work are to be sourced strictly from
          sustainably managed forests or recycled sources. FSC-certified, Queensland Cypress pine, Queensland plantation pine, timbers sourced from              INSULATION
          Queensland farm forestry, and recycled timbers are deemed to meet these conditions. If in doubt, refer to the OWNER. (NOTE: 'DNA
                                                                                                                                                                 1. STUD WALL EXTERNAL      EARTHWOOL BATTS R 2.5 + MEDIUM DUTY WALL SARKING (VAPOUR PERMEABLE)
          certification' alone does not satisfy this requirement).
                                                                                                                                                                 2. CEILING                 EARTHWOOL BATTS R 3.0
        * DO NOT WASTE WATER. Turn off taps to tank and mains water sources when no longer needed. Do not spray water unless absolutely                          3. ROOF                    EARTHWOOL SPACE BLANKET R 1.5
          necessary; sweep and mop when possible. Catch and reuse water when possible.
        * Use water-based adhesives, sealers, finishes and treatments where available in preference to solvent-based solutions.
        * Set out floor framing as necessary to ensure ffl's are flush at thresholds. (Definition of threshold: at doorways and/or change of floor material.)
        * Install all proprietary items in accordance with manufacturers instructions.                                                                           TERMITE PROTECTION
                                                                                                                                                                 1. MINIMUM 100mm EXPOSED SLAB EDGE TO ENABLE INSPECTION and AS NOTED
        * ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS 1720.1, AS 1684, AS 1684.1 AND AS 1720.2 AS APPLICABLE.                                   2. SLAB PENETRATIONS - TERMI-MESH
        * ALL TIMBER CONNECTIONS TO BE IN ACCORDANCE WITH AS1684 U.N.O.                                                                                          3. TIMBER VERANDA COLUMNS 75mm CLEARANCE TO SLAB
        * ALL PTY CONNECTORS AND FIXINGS ARE TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS.
        * MAXIMUM UNDERSIZE FOR ALL TIMBER MEMBERS SHALL BE:
              0      FOR SEASONED PINE SPECIES, OTHER SEASONED SOFTWOODS AND SEASONED HARDWOODS.
              3mm FOR UNSEASONED HARDWOODS AND CYPRESS
              4mm FOR OREGON


                                                                                                                                                                                                                                                   PRELIMINARY

                                                                                     PROJECT                                                                    REV          DESCRIPTION                 DATE
                                                                                       178 COOROY MOUNTAIN ROAD                                                                                                      TITLE PAGE AND NOTES




                                                                                                                                                                                                                                                                           25/09/2024 11:51:11 AM
                                                                                                                                                                WD1   PRELIMINARY                       25/09/2024



                                                                                                                                                                                                                     Drawn: TD            Checked: AR             REV
                                                                                     CLIENT

STUDIO: 0490 547 760                                                                   TY JONES
                                                                                                                                                                                                                     SCALE
                                                                                                                                                                                                                     As indicated @ A3
                                                                                                                                                                                                                                          DRAWING NUMBER
                                                                                                                                                                                                                                          A000
                                                                                                                                                                                                                                                                  WD1
LIC: 15256628
                                                                                                                                                                                                                                 CREATED WITH GENIUS AT RATWORKS STUDIOS
Log in to download the original file

Amended Architecturals.pdf · 13.2 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.