             GENERAL NOTES                                 COMPLIANCE NOTES                                COMPLIANCE NOTES CONTINUED                        COMPLIANCE NOTES CONTINUED                         COMPLIANCE NOTES CONTINUED

             ALL WORKS TO COMPLY WITH THE BUILDING ACT     ALL WORKS MUST EITHER COMPLY WITH THE           CLADDING                                          INSULATION                                         LIVEABLE HOUSING (NEW HOMES ONLY)
             1975, THE NATIONAL CONSTRUCTION CODE          PERFORMANCE SOLUTIONS SET OUT IN THE NCC        METAL AND PLASTIC SHEET ROOF AND WALL             THERMAL INSULATION TO BE SELECTED AND              DWELLING ACCESS TO COMPLY WITH PART 1 OF
             (NCC)2022, THE QUEENSLAND DEVELOPMENT         2022 AND STATED BELOW, OR ACHEIVE THE SAME      CLADDING TO BE DESIGNED AND INSTALLED IN          INSTALLED IN ACCORDANCE WITH AS/NZS 4859,          THE LIVEABLE HOUSING DESIGN STANDARD.
             CODE, LOCAL AUTHORITY REQUIREMENTS, AND ALL   PERFORMANCE REQUIREMENTS THROUGH                ACCORDANCE WITH AS/NZS 1562, PART 7.2 OF THE      PART 13.2 OF THE ABCB HOUSING PROVISIONS AND       DWELLING ENTRY TO COMPLY WITH PART 2 OF THE
             RELEVANT AUSTRALIAN STANDARDS. ANY            COMPLYING WITH THE DEEMED-TO-SATISFY            ABCB HOUSING PROVISIONS, AND                      MANUFACTURER'S DETAILS AND SPECIFICATIONS.         LIVEABLE HOUSING DESIGN STANDARD.
             OUTDATED STANDARDS LISTED IN THESE NOTES      SOLUTIONS AS DETAILED IN RELEVANT SECTIONS      MANUFACTURER'S DETAILS AND SPECIFICATIONS.                                                           INTERNAL DOORS AND CORRIDORS TO COMPLY
             ARE TO BE TAKEN TO REFER TO THE CURRENT       OF THE NCC 2022.                                METAL DOWNPIPES AND RAINWATER FITTINGS TO         HEALTH AND AMENITY                                 WITH PART 3 OF THE LIVEABLE HOUSING DESIGN
             EDIDITION.                                                                                    BE MANUFACTURED, SELECTED AND INSTALLED IN        INSTALL BUILDING MEMBRANES TO ALL NEW              STANDARD.
                                                           STRUCTURE                                       ACCORDANCE WITH AS/NZS 2179 AND PART 7.4 OF       EXTERNAL WALLS IN ACCORDANCE WITH AS/NZS           THE GROUND OR ENTRY LEVEL OF A DWELLING
             CHECK ALL DIMENSIONS AND LEVELS ON SITE       ALL NEW STRUCTURAL INSTALLATIONS SHOULD BE      THE ABCB HOUSING PROVISIONS. UPVC                 4200 AND PART 10.8 OF THE ABCB HOUSING             MUST HAVE AT LEAST ONE SANITARY
             PRIOR TO COMMENCING WORKS. COMPLETE SET       IN ACCORDANCE WITH AS/NZS 1170 AND PART 2.2     DOWNPIPES AND RAINWATER FITTINGS TO BE            PROVISIONS.                                        COMPARTMENT, WHICH IS TO COMPLY WITH PART
             OUT OF THE WORKS AND REPORT AND CLARIFY       OF THE ABCB HOUSING PROVISIONS. THE             MANUFACTURED, SELECTED AND INSTALLED IN           ALL MECHANICAL INSTALLATIONS ARE TO BE IN          4.2 OF THE LIVEABLE HOUSING DESIGN STANDARD,
             DISCREPANCIES TO THE DESIGNER PRIOR TO        STRUCTURAL INTEGRITY OF THE EXISTING            ACCORDANCE WITH AS 1273 AND PART 7.4 OF THE       ACCORDANCE WITH AS 1668 AND PART 10.8 OF THE       AND PART 6 WHERE RELEVANT.
             COMMENCING WORKS.                             BUILDING TO BE ADEQUATELY MAINTAINED DURING     ABCB HOUSING PROVISIONS.                          ABCB HOUSING PROVISIONS.                           AT LEAST ONE SHOWER MUST COMPLY WITH PART
                                                           CONSTRUCTION.                                   METAL ROOF AND WALL CLADDING TO HAVE              SANITARY COMPARTMENTS TO BE CONSTRUCTED            5.2 OF THE LIVEABLE HOUSING DESIGN STANDARD,
             FIGURED DIMENSIONS TAKE PRECEDENCE. DO NOT                                                    PROTECTIVE COATING APPROPRIATE TO                 IN ACCORDANCE WITH PART 10.4 OF THE ABCB           AND PART 6 WHERE RELEVANT.
             SCALE OFF DRAWINGS.                           SITE WORKS                                      ENVIRONMENT CONDITIONS IN ACCORDANCE WITH         HOUSING PROVISIONS.
                                                           REFER TO SITE SPECIFIC SOIL REPORTS OR          AS 1397 AND PART 7.2 OF THE ABCB HOUSING                                                             SUSTAINABLE HOUSING REQUIREMENTS
             CHECK SERVICES DRAWINGS INCLUDING             CLASSIFY THE SITE IN ACCORDANCE WITH PART 4.2   PROVISIONS.                                       FIRE SAFETY                                        THERMAL PERFORMANCE OF THIS BUILDING CAN
             HYDRAULIC, MECHANICAL AND ELECTRICAL FOR      OF THE ABCB HOUSING PROVISIONS AND AS 2870.     ENSURE MATERIAL COMPATIBILITY BETWEEN             SMOKE ALARMS TO BE DESIGNED, INSTALLED AND         BE SATISFIED AS PER NCC VOL 2 SPECIFICATION
             SET OUT AND SIZING OF SERVICES AND DUCTS      NECESSARY EARTHWORKS TO BE UNDERTAKEN IN        METALS SUITABLE TO ENVIRONMENT CONDITIONS         CERTIFIED IN ACCORDANCE WITH AS 3786 AND           42, BY ACHEIVING A MIN. ENERGY EFFICIENCY
             WHERE APPLICABLE.                             ACCORDANCE WITH PART 3.2 OF THE ABCB            IN ACCORDANCE WITH PART 7.2 OF THE ABCB           PART 9.5 OF THE ABCB HOUSING PROVISIONS.           STAR RATING OF 7 STARS, OR 6.5 IF IT HAS AN
                                                           HOUSING PROVISIONS.                             HOUSING PROVISIONS.                               SYSTEMS TO BE POWERED FROM CONSUMER                OUTDOOR LIVING AREA COMPLYING WITH
             COORDINATE ALL CONSULTANT DOCUMENTATION       ALL NEW EXTERNAL WORKS TO DIVERT SURFACE                                                          MAINS POWER SOURCE AND INTERCONNECTED              SPECIFICATION 42 PART C2 , OR BY COMPLYING
             AND IDENTIFY AND CLARIFY DISCREPANCIES WITH   WATER FROM BUILDINGS AND STRUCTURES TO          TIMBER CLADDING TO BE SELECTED AND                WHERE THERE IS MORE THAN ONE ALARM.                WITH THE FOLLOWING PARTS OF THE ABCB
             RELEVANT CONSULTANTS PRIOR TO COMMENCING      DISCHARGE POINTS COMPLIANT WITH PART 3.3 OF     INSTALLED IN ACCORDANCE WITH PART 7.5 OF THE      PORTABLE FIRE EXTINGUISHERS AND BLANKETS           HOUSING PROVISIONS—
             RELATED WORKS.                                THE ABCB HOUSING PROVISIONS.                    ABCB HOUSING PROVISIONS AND                       TO BE PROVIDED DURING CONSTRUCTION IN              PART 13.2, FOR THE BUILDING FABRIC; AND
                                                                                                           MANUFACTURER'S SPECIFICATIONS.                    ACCORDANCE WITH AS 2444.                           PART 13.3, FOR THE EXTERNAL GLAZING AND
             CHECK ONSITE DIMENSIONS PRIOR TO              SLABS AND FOOTINGS                              FIBRE CEMENT BOARD AND SHEET CLADDING AND         ELECTRICAL INSTALLATIONS TO BE UNDERTAKEN          SHADING; AND
             FABRICATION OF WINDOWS, DOORS AND JOINERY.    CONCRETE SLABS AND FOOTINGS, INCLUDING          LINING TO BE SELECTED AND INSTALLED IN            IN ACCORDANCE WITH AS 3000.                        PART 13.4, FOR BUILDING SEALING; AND
                                                           STEEL REINFORCEMENT, TO BE DESIGNED,            ACCORDANCE WITH PART 7.5 OF THE ABCB                                                                 PART 13.5, FOR CEILING FANS.
             REFER TO BUILDING APPROVAL FOR SPECIFIC       INSTALLED AND CERTIFIED IN ACCORDANCE WITH      HOUSING PROVISIONS, AS/NZS 2908, AS/NZS 1859      PLUMBING AND DRAINAGE                              ENERGY EFFICIENT (E.E.) LIGHTING:
             CONDITIONS AND ADDITIONAL REQUIREMENTS.       AS 2870 AND SECTION 4.2 OF THE ABCB HOUSING     AND MANUFACTURERS SPECIFICATIONS.                 PLUMBING AND DRAINAGE INSTALLATIONS                A MINIMUM OF 80% OF TOTAL FIXED INTERIOR
                                                           PROVISIONS.                                     PARTICLEBOARD FLOORING TO BE INSTALLED IN         INCLUDING WATER SERVICES, SANITARY DRAINAGE        ARTIFICIAL LIGHTING TO THE DWELLING AND
             ALL NEW SERVICES TO CONNECT TO EXISTING ON                                                    ACCORDANCE WITH AS 1860 AND NCC 2022 H1.          AND STORMWATER DRAINAGE TO BE INSTALLED IN         ATTACHED GARAGE SHALL BE ENERGY EFFICIENT
             SITE UTILITIES. CONFIRM SUITABILITY AND       REINFORCED CONCRETE                                                                               ACCORDANCE WITH AS/NZS 3500 AND PARTS 3.3          LIGHTING TO COMPLY WITH QDC MP4.1.
             CAPACITY PRIOR TO COMMENCING WORKS.           CONCRETE AND CONCRETE STRUCTURES TO BE          GLAZING                                           AND 7.4 OF THE ABCB HOUSING PROVISIONS.            TAPWARE:
                                                           MANUFACTURED, DESIGNED AND INSTALLED IN         GLASS AND GLAZING TO BE SELECTED AND              INSTALLATIONS TO ACCOMMODATE FOR                   ALL SHOWER HEADS AND TAPWARE TO LAUNDRY
             ALL PROPIETARY MATERIALS SHALL BE USED AND    ACCORDANCE WITH AS 3600.                        INSTALLED IN ACCORDANCE WITH AS 1288 AND          POTENTIAL MOVEMENT OF SOIL. REFER TO SOIL          TUBS, KITCHEN SINKS AND
             FIXED STRICTLY IN ACOORDANCE WITH                                                             PART 8.4 OF THE ABCB HOUSING PROVISIONS.          REPORTS FOR CLASSIFICATION.                        BASINS MUST HAVE A MINIMUM 3-STAR WATER
             MANUFACTURER'S WRITTEN INSTRUCTIONS FOR       MASONRY                                         WINDOWS AND EXTERNAL GLAZED DOORS ARE TO          HOT WATER RETICULATION SHALL BE                    EFFICIENCY LABELLING AND STANDARDS RATING,
             USE UNDER THE CONDITIONS APPLICABLE.          PROVIDE DAMP PROOF COURSES AND FLASHINGS        BE DESIGNED, MANUFACTURED AND INSTALLED IN        TEMPERATURE CONTROLLED TO 50ºC OR BELOW            TO COMPLY WITH QDC MP4.1.
                                                           TO NEW MASONRY WALL INSTALLATIONS IN            ACCORDANCE WITH AS 2047 AND PART 8.2 OF THE       TO BATHS SHOWERS AND BASINS IN ACCORDANCE          TOILETS:
             SURFACE WATER DRAINAGE MUST BE PREVENTED      ACCORDANCE WITH AS/NZS 2904, AND PARTS 5.7.4    ABCB HOUSING PROVISIONS.                          WITH AS 3500.                                      TOILET CISTERNS MUST HAVE DUAL FLUSH
             FROM ENTERING THE BUILDING WITH FGL SLOPING   AND 12.3 OF THE ABCB HOUSING PROVISIONS.        GLAZED PANELS CAPABLE OF BEING MISTAKEN                                                              CAPABILITY AND HAVE A MINIMUM 4-STAR WATER
             AWAY FROM THE BUILDING AND FINISHED SLAB      MASONRY STRUCTURES TO BE DESIGNED AND           FOR UNOBSTRUCTED OPENINGS ARE TO BE MADE          TERMITE RISK MANAGEMENT                            EFFICIENCY LABELLING AND STANDARDS RATING
             LEVELS.                                       INSTALLED IN ACCORDANCE WITH AS 3700 AND        APPARENT WITH PERMANENT DECALS OR VISION          TERMITE MANAGEMENT BARRIERS AND                    TO COMPLY WITH QDC MP4.1.
                                                           PART 5 OF THE ABCB HOUSING PROVISIONS.          STRIPS TO INDICATE ITS PRESENCE.                  INSTALLATIONS TO BE DESIGNED AND INSTALLED         RAINWATER TANKS:
                                                           MASONRY STRUCTURES IN SMALL BUILDINGS TO        GARAGE AND LARGE PANEL DOORS TO BE                TO AREAS WITHIN PROPOSED WORKS IN                  A RAINWATER TANK WITH A MINIMUM STORAGE
                                                           BE DESIGNED AND INSTALLED IN ACCORDANCE         DESIGNED AND INSTALLED IN ACCORDANCE WITH         ACCORDANCE WITH AS 3660, AS 2870, AND PART         CAPACITY OF 5000 LITRES MUST BE INSTALLED TO
                                                           WITH AS 4773 AND PART 5 OF THE ABCB HOUSING     AS/NZS 4505 AND PART 2.2 OF THE ABCB HOUSING      3.4 OF THE ABCB HOUSING PROVISIONS.                AS 3500 - PLUMBING AND DRAINAGE AND AS
                                                           PROVISIONS.                                     PROVISIONS.                                                                                          PER QDC MP4.2 AND LOCAL AUTHORITY
                                                                                                                                                             WORKPLACE HEALTH AND SAFETY                        REQUIREMENTS.
                                                           FRAMING                                         WATERPROOFING                                     BUILDER SHALL COMPLY WITH ALL WORKPLACE
                                                           TIMBER FRAMED CONSTRUCTION SHOULD BE            WET AREAS TO BE WATERPROOFED IN                   HEALTH AND SAFETY REQUIREMENTS REQUIRED
                                                           DESIGNED AND INSTALLED IN ACCORDANCE WITH       ACCORDANCE WITH AS 3740 AND PART 10.2 OF THE      BY LEGISLATION FOR THE CONSTRUCTION OF THE
                                                           AS1684 AND NCC 2022 PART H1D6.                  ABCB HOUSING PROVISIONS.                          DWELLING AND SHALL ASSESS ALL WORKPLACE
                                                           TIMBER STRUCTURES ARE TO BE DESIGNED IN         EXTERNAL WATERPROOFING MEMBRANES TO BE            HEALTH AND SAFETY ISSUES BEFORE
                                                           ACCORDANCE WITH AS 1720.1 AND NCC 2022 PART     DESIGNED AND INSTALLED IN ACCORDANCE WITH         COMMENCEMENT OF CONSTRUCTION AND LIAISE
                                                           H1D6. NAILPLATE TIMBER ROOF TRUSSES TO          AS 4654 AND NCC 2022 PART H2.                     WITH THE DESIGNER IF NECESSARY TO
                                                           MANUFACTURERS DETAILS AND AS 1720.5.                                                              AVOID/MINIMISE RISKS DURING CONSTRUCTION.
                                                                                                           STAIRWAY AND RAMP CONSTRUCTION
                                                           STEEL FRAMED CONSTRUCTION SHOULD BE             SLIP RESISTANCE OF LANDINGS, STAIRS AND
                                                           DESIGNED AND INSTALLED IN ACCORDANCE WITH       RAMPS TO BE IN ACCORDANCE WITH PART 11.2 OF
                                                           AS/NZS 4600 AND NCC 2022 PART H1D6. STEEL       THE ABCB HOUSING PROVISIONS AND AS 4586.
                                                           STRUCTURES TO BE DESIGNED, INSTALLED AND
                                                           CERTIFIED IN ACCORDANCE WITH AS 4100 AND NCC
                                                           2022 PART H1D6.
                                                                                                                                                                                                                                                  PRELIMINARY

                                                                   PROJECT                                                                           REV           DESCRIPTION                     DATE
                                                                     178 COOROY MOUNTAIN ROAD                                                                                                                  NOTES AND LEGENDS




                                                                                                                                                                                                                                                                      25/09/2024 11:51:15 AM
                                                                                                                                                     WD1   PRELIMINARY                            25/09/2024



                                                                                                                                                                                                               Drawn: TD                Checked: AR            REV
                                                                   CLIENT

STUDIO: 0490 547 760                                                 TY JONES
                                                                                                                                                                                                               SCALE
                                                                                                                                                                                                               1 : 50 @ A3
                                                                                                                                                                                                                                        DRAWING NUMBER
                                                                                                                                                                                                                                        A001
                                                                                                                                                                                                                                                               WD1
LIC: 15256628
                                                                                                                                                                                                                            CREATED WITH GENIUS AT RATWORKS STUDIOS
Log in to download the original file

Amended Architecturals.pdf · 13.2 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.