                                                                                Construction Management Plan
                                                                                         for Infinity Apartments
4.       COUNCIL ASSETS
4.1 Parking Meters & Spaces

     During the course of construction, McNab will be seeking to have three parking bays designated as
     “Construction Zone” to facilitate safe and efficient loading and unloading of materials. Where any
     car space closures are required, approvals/permits must be obtained from the relevant authority/s.

4.2 Ground Water and Stormwater Discharge

     During construction ground and stormwater will need to be discharged from site. Prior to discharge
     all water will be treated in line with Noosa Council requirements and test results kept on site. Water
     will then be discharged into existing kerb and channel system.

     Sediment and erosion control measures will be established before ground disturbance in line with
     civil engineering plan 28929-OW2.1

     Sediment and erosion controls will be monitored daily and adjusted as the project evolves. Any
     deviation for approved plans will be approved by the project civil engineer.

     Final Stormwater service will be provided to the site in accordance with operational works
     OPW19/0205 lodged on 17.09.2019. Stormwater, after treatment, will be discharged into the
     existing kerb and channel system via multiple kerb adaptors.



5.       AUTHORITY CONNECTIONS
5.1 Electrical/Telecommunications Infrastructure

     Electrical infrastructure will be installed by McNab within the footpath to enable ENERGEX to supply
     power to the development. Power will be drawn for an existing greenbouy. Minimal disruptions are
     anticipated during these works.

5.2 Potable Water Service

     Potable water service will be provided to the site in accordance with SCG Engineering Plans 28292-
     OW4.1 B. Unity Water approval will be gained prior to works being carried out.

5.3 Waste Water Service

     Wastewater service will be provided to the site in accordance with SCG Engineering Plans 28292-
     OW4.1 B. Unity Water approval will be gained prior to works being carried out.




                                                        05-DOC-001 Rev 0 - Construction Management Plan p9 of 16

Used in these records

About this file

File size
7.5 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Construction Mangement Plan Reference Document OPW19-0239.pdf · 7.5 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.