Council archive · source document
Further info - ENTRY FACILITIES-PACKAGE 10.03.2020 · 51901.3604.02
Original PDF page 14, section 1. The text section number identifies this passage in the reader.
GROUNDCOVER AS SPECIFIED.
SHRUB AS SPECIFIED.
SHRUBS AND GROUNDCOVERS AS
SHRUBS AND GROUNDCOVERS AS SPECIFIED SET VERTICAL. REFER TO
SPECIFIED SET VERTICAL. REFER TO FERN AS SPECIFIED. PLANS AND PLANT SCHEDULE.
PLANS AND PLANT SCHEDULE.
CROWN BED AT CENTRE. 100MM OF MULCH AS SPECIFIED.
100MM OF MULCH AS SPECIFIED. ENSURE MULCH 25MM MIN
ENSURE MULCH 25MM MIN CLEAR OF PLANT STEM.
CLEAR OF PLANT STEM. 100MM OF MULCH AS SPECIFIED.
PLACE SLOW RELEASE NATIVE FERTILISER, MINIMUM 300MM DEPTH OF FIABLE IMPORTED
MINIMUM 300MM DEPTH OF FIABLE IMPORTED WATER CRYSTALS AND SOIL CONDITIONER TOP AS SPECIFIED.
TOP SOIL AS SPECIFIED AS SPECIFIED.
SLOW RELEASE NATIVE FERTILISER AS PER
SLOW RELEASE NATIVE FERTILISER AS PER IMPORTED FERN COMPOSTED SOIL AS MANUFACTURERS RECOMMENDATIONS.
MANUFACTURERS RECOMMENDATIONS. SPECIFIED. WATER CRYSTALS AS PER MANUFACTURERS
WATER CRYSTALS AS PER MANUFACTURERS CONSOLIDATED DEPTH. SPECIFICATION (AVOID PLACING UNDER ROOTBALL).
SPECIFICATION (AVOID PLACING UNDER ROOTBALL). CULTIVATE SUBGRADE TO A DEPTH
CULTIVATE SUBGRADE TO A DEPTH CULTIVATE SUBGRADE TO A DEPTH OF OF 150MM.
OF 150MM. 100MM.
EXISTING SUBGRADE.
EXISTING SUBGRADE. EXISTING SUBGRADE.
03 MULCHED GARDEN GROUNDCOVER PLANTING - TYPICAL DETAIL
01 MULCHED GARDEN BED SHRUB PLANTING - TYPICAL DETAIL 02 MULCHED GARDEN FERN PLANTING - TYPICAL DETAIL SCALE 1:20
SCALE 1:20 SCALE 1:20
HESSIAN 50MM WIDTH NOTES:
ROOT BARRIER TO BE APPLIED UNLESS
N
OTHERWISE SPECIFIED TO IRC APPROVAL.
STAKE IRRIGATION SYSTEM AS SPECIFIED.
INSTALL PVC AG-PIPE SUBSOIL DRAINAGE AS
SPECIFIED REFER TO DETAIL.
W E STAKE SIZES FOR PLANT SIZES:
1M WIDE MULCHED COLLAR SIZE STAKE
TREE 45LITRE 50X50MM
100LITRE 75X75MM
200/400LITRE 100X100MM
S
PLAN VIEW - STAKE
POSITIONING AND HESSIAN
LOOP - EXAMPLE WHEN
PREVAILING WIND IS SOUTH
EAST
100mm DEEP MULCH COLLAR
TAPERED DOWN IN CENTRE
TO FORM WATERING BASIN.
ADVANCED TREE AS SPECIFIED. REFER TO
PLANTING PLAN. ADVANCED PALM AS SPECIFIED. REFER TO
PLANTING PLAN.
REFER TO TABLE FOR STAKE SIZES. STAKES TO
BE F14 HW NON-TREATED STAKES FREE FROM 50MM WIDTH HESSIAN SECURED LOOSELY TO
KNOTS AND WARPS ETC. STAKES TO BE DRIVEN PALM AND FIXED TO STAKE WITH GALVANIZED
IN TO HEIGHT TO ENSURE STAKE DOES NOT FLAT HEAD NAILS. HEIGHT OF TIE TO BE ONE
DAMMAGE LOWER LIMBS. STAKES TO BEDRIVEN THIRD TO ONE HALF THE OVERALL HEIGHT OF
CENTRALLY POINTED AND DRIVEN VERTICALLY TREE. REFER TO PLAN VIEW.
INTO GROUND OUTSIDE OF ROOTBALL. LOCATE
PLAN VIEW. REFER TO TABLE FOR STAKE SIZES. STAKES TO
BE F14 HW NON-TREATED STAKES FREE FROM
50MM WIDTH HESSIAN SECURED LOOSELY TO KNOTS AND WARPS ETC. STAKES TO BE DRIVEN
TREE AND FIXED TO STAKE WITH GALVANIZED IN TO HEIGHT TO ENSURE STAKE DOES NOT
FALL FALL
FLAT HEAD NAILS. HEIGHT OF TIE TO BE ONE DAMMAGE ROOT BALL. STAKES TO BEDRIVEN
THIRD TO ONE HALF THE OVERALL HEIGHT OF CENTRALLY POINTED AND DRIVEN ANGLED INTO
TREE. REFER TO PLAN VIEW. GROUND OUTSIDE OF ROOTBALL. LOCATE TO
BACK OF PALM FROM MAIN VIEW SIDE.
100MM DEEP MULCH COLLAR TAPERED DOWN IN
CENTRE TO FORM WATERING BASIN. 100MM DEEP MULCH COLLAR TAPERED DOWN IN
POT .
CENTRE TO FORM WATERING BASIN.
TREE PIT TO BE EXCAVATED TO DEPTH OF POT .
ROOTBALL, BACKFILLED WITH 50% SOIL AND PALM PIT TO BE EXCAVATED TO DEPTH OF
POT .
MAXIMUM 2% ORGANIC CONTENT, FIRMING ROOTBALL, BACKFILLED WITH 50% SOIL AND
POT .
PROGESSIVELY. MAXIMUM 2% ORGANIC CONTENT, FIRMING
PROGESSIVELY.
SCARIFY ALL SIDES OF PLANTING PIT. AND
ENSURE ALL SIDES ARE POROUS. RIP CLAY SCARIFY ALL SIDES OF PLANTING PIT. AND
SURFACES. ENSURE ALL SIDES ARE POROUS. RIP CLAY
ROOTBALL WATER CRYSTALS AS SPECIFIED. APPLIED PER SURFACES.
DEPTH. MANUFACTURERS RECOMMENDATIONS. AVOID ROOTBALL WATER CRYSTALS AS SPECIFIED. APPLIED PER
FOR TENDER
PLACING UNDER ROOT BALL. DEPTH. MANUFACTURERS RECOMMENDATIONS. AVOID
PLACING UNDER ROOT BALL.
SLOW RELEASE FERTILISER AS PER
MANUFACTURERS SPECIFICATION. SLOW RELEASE FERTILISER AS PER
MANUFACTURERS SPECIFICATION.
CULTIVATE SUBGRADE TO 150mm DEPTH.
CULTIVATE SUBGRADE TO 150MM DEPTH.
IMPORTANT NOTE: REFER TO PLANT SCHEDULE FOR COMPLETE DETAIL. TREES TO BE 2500MM
EXISTING SUBGRADE.
CLEAR TRUNK AND TRUNKS PARALLEL TO ROAD AND GROWTH DIRECTION AWAY FROM ROAD.
EXISTING SUBGRADE.
GENERALLY 2X WIDTH
OF ROOTBALL GENERALLY 2X WIDTH
OF ROOTBALL
04 ADVANCED TREE PLANTING - TYPICAL DETAIL 05 EXGROUND TREE PLANTING - TYPICAL DETAIL 06 ADVANCED PALM PLANTING - TYPICAL DETAIL
SCALE 1:20 SCALE 1:20 SCALE 1:20
NOT FOR CONSTRUCTION
THE BUILDER / CONTRACTOR SHALL VERIFY JOB DIMENSIONS PRIOR TO ANY WORK COMMENCING. FIGURED DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED WORK.
CONLON DATE ISS
09.03.20 D
DESCRIPTION
FOR TENDER
CHKD
MC
CLIENT
CULGOA POINT BEACH PROPOSED ALTERATIONS & LANDSCAPE DETAILS
PROJECT LANDSCAPE DOCUMENTATION PACKAGE PROJECT. NO.
420
DWG. NO. ISSUE
GROUP
P 07 5338 8690 E [email protected]
29.10.19 C
09.10.19 B
12.03.19 A
FOR TENDER
FOR TENDER
FOR TENDER
MC
MC
MC RESORT BODY CORPORATE UPGRADES - STAGE 02 ENTRY AREA
THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF CONLON GROUP PTY. LTD. AND MUST NOT BE RETAINED, COPIED/REPRODUCED OR USED WITHOUT WRITTEN AUTHORITY.
SCALE
A1 LP401 D
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Further info - ENTRY FACILITIES-PACKAGE 10.03.2020.pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.