Page text shows just the words. Original shows the document exactly as it was published.

                                              "THIS PLAN IS TO BE READ IN
                                                CONJUNCTION WITH THE
                                                SPECIFICATIONS, QUOTE
                                        AND BUILDING CONTRACT. IF ITEMS ARE
                                             NOT STATED IN ANY OF THESE
                                                     DOCUMENTS,
                                         IT IS NOT INCLUDED IN YOUR BUILD."

                                                                   NOTES                                                                                                                                                                               PLAN LEGEND                                                                                                                             CLIENT:
                                                                                                                                                                                                                                                                                                                            PLEASE READ CAREFULLY
                                                                                                                                                            10. Protection against subterranean termites shall be in accordance with AS
                                                                   1. Written dimensions take precedence over scale.                                            3660-Pt 1 2001. Provided treatment: Visual Barrier System to perimeter with            afl = above floor level    ref = refrigerator prov.       THIS PLAN CERTIFIED CORRECT IS THE ONE REFERRED TO IN THE             D. COUTTS & A. BRETT
                                                                                                                                                                                                                                                                                                                   CONTRACT & SPECIFICATIONS AND I UNDERSTAND CHANGES
                                                                   2. Builder to verify all dimensions and levels prior to commencement of construction.        approved collars/barriers at slab penetrations.                                        hd = head at 2100 afl.     mw = microwave prov.           HEREAFTER MAY NOT BE POSSIBLE. THESE PLANS SUPERCEDE ALL
                                                                   3. All internal dimensions stated are frame size - excluding linings.                    11. HWS unit (constant flow) with 5 star energy efficiency rating to comply                fw = floor waste           dw = dishwasher prov.                     OTHER PREVIOUS PLANS OR SKETCHES.
                                                                   4. This building has been designed in accordance with AS 1684.2 - 2006 (Residential           with "Sustainable Buildings" QDC pt 29, AS/NZs 6400:2005.                                  = smoke detector      pty = pantry                                                                                        Lot 31 Butcherbird Lande
                                                                      timber framed construction).                                                          12. Rainwater tanks, lighting and plumbing fixtures & fittings to comply with QDC          vb = vanity basin          wm = washing machine prov.                                                                                RIDGEWOOD
                    Stroud Homes Pty Ltd                           5. Supplier may substitute lintels for those of equal strength to span ratio.                PART 29 & 25, 'Sustainable Buildings' QDC pt 29 & 25 AS/Nzs 300.1.2003                 obs = obscure glazing      ghw = gas hot water unit
                    ABN: 49 107 897 736 QBSA Lic No: 1083367       6. All structural sizes to be read in-conjunction with structural engineers drawings &       AS/NZS 6400:2005.                                                                      mb = meter box             tr = towel rail                                                                            MODEL:                      JOB
                                                                                                                                                                                                                                                                                                               OWNER/S                                                                                           20L031BU
                                                                      details.                                                                              13. Lift off hinges to all WC doors to comply with Australian Standards.                   dp = downpipe              trh = toilet roll holder                                                                   Springleigh 204 Classic     No.
                    107 Sugar Road   Telephone:   Email:           7. Articulation joints to complay with 3.3.1.8 BCA Vol 2.                                14. Stair construction to comply with Pt 3.9.1 and balustrades to comply with pt           ohc = overhead cupboard    HC = garden tap
                                                                                                                                                                                                                                                                                                               WITNESS                                 DATE
                    Maroochydore     07 5444 2521 Daniel.chapman   8. Mechanical Ventilation to comply with 3.8.5 Bca Vol 2.                                    3.9.2 BCA Vol 2.                                                                                                                                                                                             ISSUE/DATE:                 SHEET
                    QLD              Mobile:      @stroudhomes.                                                                                                                                                                                                                                                                                                                                           No.
                                                                   9. Smoke alarms to comply with 3.7.2 BCA Vol 2 (wired-in)                                15. DCP & flashings to comply with Pt 3.3.4 BCA Vol 2
                    4558             0402 864 305 com.au                                                                                                                                                                                        C   2017 REPRODUCTION IN PART OR WHOLE IS STRICTLY FORBIDDEN
                                                                                                                                                                                                                                                                                                                                                                             PRELIM ISSUE 1 : 03/11/20            1 OF 08
GSPublisherVersion 0.0.100.100
Log in to download the original file

Architecturals.pdf · 718 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.