Original source · versioned page text
Architecturals
Exist
ing
Hous
Well e
Away
BUS
H LA
ND
No M
k
Foun
d
326°30' No M
k
156.68 Foun
d
N
Den Den
Vege se Vege se
157.19
tation
61°40'30"
tation
191.6 0"
Den
30'4 Vege se
8
tation
249°
Exist
ing
Hous
Well e
Away
No M
k
Foun
10,000
TO OM
d
10,623 75 P
Su
TO WA
LL
TBM rveye DP DP DP
160.17
AHD Peg
d Are '
134°55
DP
RL /
a DP
PROPOSED RESIDENCE
SETOU
m2 DP
02.25
0
T EXTRA DP DP DP
This
addr
Contour FEES
ALERT
3,958 25 TO OMP
ess the and Feat
4,525 TO WALL
and / ure Surv (Desig
or miss location of
6,000 TO WALL
28.803
extra ing boun boun ey as prep ner/
5,365 5 TO OMP
cont Builde
contact rol work dary daries. ared
by Axis
this offic to enab pegs, Axis Because Surv r Etc
e for le Surv of the eys does .)
furth us to seto eys age
er advi ut any will requ of the subj not 27.7 m2
ce. prop ire addi ect plan
Peg
osed
build tional fees /
ing work for
. Plea
150°18'
se
Foun
d
OVERALL SITE PLAN Peg
ane
Foun
d
EMT A
erbird L
Butch
SCALE 1 : 1000
NOTES PLAN LEGEND CLIENT:
PLEASE READ CAREFULLY
10. Protection against subterranean termites shall be in accordance with AS
1. Written dimensions take precedence over scale. 3660-Pt 1 2001. Provided treatment: Visual Barrier System to perimeter with afl = above floor level ref = refrigerator prov. THIS PLAN CERTIFIED CORRECT IS THE ONE REFERRED TO IN THE D. COUTTS & A. BRETT
CONTRACT & SPECIFICATIONS AND I UNDERSTAND CHANGES
2. Builder to verify all dimensions and levels prior to commencement of construction. approved collars/barriers at slab penetrations. hd = head at 2100 afl. mw = microwave prov. HEREAFTER MAY NOT BE POSSIBLE. THESE PLANS SUPERCEDE ALL
3. All internal dimensions stated are frame size - excluding linings. 11. HWS unit (constant flow) with 5 star energy efficiency rating to comply fw = floor waste dw = dishwasher prov. OTHER PREVIOUS PLANS OR SKETCHES.
4. This building has been designed in accordance with AS 1684.2 - 2006 (Residential with "Sustainable Buildings" QDC pt 29, AS/NZs 6400:2005. = smoke detector pty = pantry Lot 31 Butcherbird Lande
timber framed construction). 12. Rainwater tanks, lighting and plumbing fixtures & fittings to comply with QDC vb = vanity basin wm = washing machine prov. RIDGEWOOD
Stroud Homes Pty Ltd 5. Supplier may substitute lintels for those of equal strength to span ratio. PART 29 & 25, 'Sustainable Buildings' QDC pt 29 & 25 AS/Nzs 300.1.2003 obs = obscure glazing ghw = gas hot water unit
ABN: 49 107 897 736 QBSA Lic No: 1083367 6. All structural sizes to be read in-conjunction with structural engineers drawings & AS/NZS 6400:2005. mb = meter box tr = towel rail MODEL: JOB
OWNER/S 20L031BU
details. 13. Lift off hinges to all WC doors to comply with Australian Standards. dp = downpipe trh = toilet roll holder Springleigh 204 Classic No.
107 Sugar Road Telephone: Email: 7. Articulation joints to complay with 3.3.1.8 BCA Vol 2. 14. Stair construction to comply with Pt 3.9.1 and balustrades to comply with pt ohc = overhead cupboard HC = garden tap
WITNESS DATE
Maroochydore 07 5444 2521 Daniel.chapman 8. Mechanical Ventilation to comply with 3.8.5 Bca Vol 2. 3.9.2 BCA Vol 2. ISSUE/DATE: SHEET
QLD Mobile: @stroudhomes. No.
9. Smoke alarms to comply with 3.7.2 BCA Vol 2 (wired-in) 15. DCP & flashings to comply with Pt 3.3.4 BCA Vol 2
4558 0402 864 305 com.au C 2017 REPRODUCTION IN PART OR WHOLE IS STRICTLY FORBIDDEN
PRELIM ISSUE 1 : 03/11/20 2 OF 08
GSPublisherVersion 0.0.100.100
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.