MCU21 0041 Approved Plans
Original PDF page 11, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn APPROVED PLAN
MCU21/0041
NOOSA COUNCIL
8 JUNE 2022
2190
Colorbond Custom orb roof
Rendered 75 mm foamboard cladding with compliant render O/H sheeting fixed to manufacturers
finish to meet BAL 19 fixed to manufacturers specification. 1030 specification for N3 wind loading.
1188 (5° pitch).
O/H
Colorbond gutter and fascia O/H
to match roofing. Fix to
manufacturers specification. Scyon Stria 325 Cladding fixed to
manufacturers specification.
ceiling
Selected Solid / Glass (500 / 500mm) head
balustrade with Powder coated Handrail over.
125mm max. gap. 1000 high.
2700
2400
Colorbond Custom orb roof sheeting
fixed to manufacturers specification
for N3 wind loading. (5° pitch).
first floor
ceiling
Approved Face Fixed Glass Pool head
ceiling
Fence to comply with A.S. 1926. head
Min 1200 high max 100 mm gap.
2700
2400
2700
2400
floor
Nom. 200 thick Pool walls to guest floor
engineers specification. F.G.L. 225 min.
F.G.L. 225 min.
Approx. Existing
Ground Line.
200 series Blockwork walls with with select
stone finish over to manufacturers specification Approx. Proposed
Ground Line.
Rendered 200 series blockwork
walls to manufacturers specification. Timber look aluminium
framed windows to
Rendered 250 brick veneer manufacturers specification.
walls in accordance with
manufacturers specification.
NOTE : D
The Proposed Building is located in a bushfire prone area.
Building construction to be in accordance with N.C.C. part
3.7.4 & A.S. 3959 - 2011 (South Elevation B.A.L. 12.5 &
North, East & West Elevations B.A.L. 19) as per private BAL
Assessor's decision. Refer to BPAD Bushfire Planning &
Design (Adrian Hansen) Bush fire Risk Assessment and
Bushfire Risk Management Plan. The author of these drawings NOTE :
accepts no responsibility whatsover for the assessment of the
B.A.L. Refer to page 102 & 103 for further construction
All exposed Timbers to be specified on North, East and West
elevations must be in accordance with B.A.L. 19. NORTH ELEVATION - B.A.L 19
requirements. Scale 1 : 100
AK B U I L D I N G D E S I G N
Dean White & Vivienne Savill Working Drawings REV D A3
DATE: 18/05/2022
© Copyright 2 Lakeway Dr. DRAWING No:
T. 07 5443 4200 E. [email protected]
A. Suite 9/50 Aerodrome Rd Maroochydore
QBCC 1060583 ABN 95 621 039 731
P.O. Box 116 Cotton Tree Qld 4558 Cooroibah 20138A / 403