MCU21/0041
NOOSA COUNCIL
8 JUNE 2022
75mm foamboard walls with compliant render
finish to meet BAL 12.5 to manufacturers
specification. Colorbond Custom orb roof sheeting
fixed to manufacturers specification
Colorbond Custom orb roof sheeting for N3 wind loading. (5° pitch).
fixed to manufacturers specification
for N3 wind loading. (5° pitch).
Selected Glass balustrade with
Powder coated Handrail over.
125mm max. gap. 1000 high.
Scyon Stria 325 Cladding fixed to ceiling
manufacturers specification.
head
2700
Colorbond gutter and fascia
2100
to match roofing. Fix to
manufacturers specification.
first floor
Timber look aluminium ceiling
framed windows to head
manufacturers specification.
2700
2400
floor
Approx. Existing F.G.L. 225 min.
Ground Line.
Approx. Proposed Nom. 200 thick Pool walls to
Ground Line. engineers specification.
Rendered 250 brick veneer 3 Approved Face Fixed Glass Pool
walls in accordance with 405 Fence to comply with A.S. 1926.
manufacturers specification. Min 1200 high max 100 mm gap.
Rendered 200 series blockwork 200 series Blockwork walls with with
walls to manufacturers specification. select stone finish over to manufacturers
specification
Decobatten 100x50 Posts
@ 250mm centres to All stairs and balustrades to be in
manufacturers specification. accordance with N.C.C. - 2019 Part 3.9.1.
NOTE : Balustrades 1000 min. above F.L. with
The Proposed Building is located in a bushfire prone area. 125mm max. openings.
Building construction to be in accordance with N.C.C. part D
3.7.4 & A.S. 3959 - 2011 (South Elevation B.A.L. 12.5 &
North, East & West Elevations B.A.L. 19) as per private BAL
Assessor's decision. Refer to BPAD Bushfire Planning &
Design (Adrian Hansen) Bush fire Risk Assessment and NOTE :
Bushfire Risk Management Plan. The author of these drawings
accepts no responsibility whatsover for the assessment of the
B.A.L. Refer to page 102 & 103 for further construction
All exposed Timbers to be specified on South elevation must
be in accordance with B.A.L. 12.5. SOUTH ELEVATION - B.A.L 12.5
Refer Page 102 for approved timber species. Scale 1 : 100
requirements.
AK B U I L D I N G D E S I G N
Dean White & Vivienne Savill Working Drawings REV D A3
DATE: 18/05/2022
© Copyright 2 Lakeway Dr. DRAWING No:
T. 07 5443 4200 E. [email protected]
A. Suite 9/50 Aerodrome Rd Maroochydore
QBCC 1060583 ABN 95 621 039 731
P.O. Box 116 Cotton Tree Qld 4558 Cooroibah 20138A / 402