Log in to see the plans as drawn APPROVED PLAN
MCU21/0041
NOOSA COUNCIL
8 JUNE 2022
Scyon Stria 325 Cladding fixed to Scyon Linea Weatherboard
manufacturers specification. 150 Cladding fixed to
manufacturer specification.
Rendered 250 brick veneer Decobatten 100x50 Posts
walls in accordance with @ 250mm centres to
manufacturers specification. manufacturers specification.
600 600 2
Colorbond Custom orb roof sheeting O/H O/H Rendered 75 mm foamboard
404
fixed to manufacturers specification cladding with compliant
for N3 wind loading. (5° pitch). render finish to meet BAL 19
600 fixed to manufacturers
600
O/H specification.
O/H
Scyon Stria 325 Cladding fixed to
manufacturers specification.
ceiling
head
Timber look aluminium
framed windows to
manufacturers specification.
2700
2400
Colorbond gutter and fascia 600
to match roofing. Fix to O/H
manufacturers specification. first floor
ceiling
head
ceiling
head
2700
2400
2700
2400
floor
guest floor
F.G.L. 225 min.
F.G.L. 225 min.
Approx. Existing
Rendered 200 series blockwork Ground Line.
walls to manufacturers specification. 1
404 Approx. Proposed
200 series Blockwork walls with select Ground Line.
stone finish over to manufacturers specification.
Selected Panel Lift Garage
Timber framed door to manufacturers specification. door to manufacturers
Approved Timber species to meet B.A.L. 19 specification.
NOTE :
The Proposed Building is located in a bushfire prone area. D
Building construction to be in accordance with N.C.C. part
3.7.4 & A.S. 3959 - 2011 (South Elevation B.A.L. 12.5 &
North, East & West Elevations B.A.L. 19) as per private BAL
Assessor's decision. Refer to BPAD Bushfire Planning &
Design (Adrian Hansen) Bush fire Risk Assessment and
NOTE :
Bushfire Risk Management Plan. The author of these drawings
accepts no responsibility whatsover for the assessment of the
B.A.L. Refer to page 102 & 103 for further construction
All exposed Timbers to be specified on North, East and West
elevations must be in accordance with B.A.L. 19.
WEST ELEVATION - B.A.L 19
Scale 1 : 100
requirements.
AK B U I L D I N G D E S I G N
Dean White & Vivienne Savill Working Drawings REV D A3
DATE: 18/05/2022
© Copyright 2 Lakeway Dr. DRAWING No:
T. 07 5443 4200 E. [email protected]
A. Suite 9/50 Aerodrome Rd Maroochydore
QBCC 1060583 ABN 95 621 039 731