MCU21 0041 Approved Plans
Original PDF page 9, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn APPROVED PLAN
MCU21/0041
NOOSA COUNCIL
8 JUNE 2022
Scyon Linea Weatherboard 150 Colorbond Custom orb roof
Cladding fixed to manufacturers sheeting fixed to manufacturers
specification. specification for N3 wind loading.
(5° pitch).
Selected Solid / Glass (500 / 500mm)
balustrade with Powder coated Handrail over.
125mm max. gap. 1000 high. 600 Rendered 250 brick veneer
O/H walls in accordance with
600 manufacturers specification.
O/H
Timber look aluminium
ceiling framed sliding doors to
head manufacturers specification.
600
2700
2400
O/H
Colorbond gutter and fascia
to match roofing. Fix to
first floor manufacturers specification.
ceiling
head
ceiling
head
2700
2400
2700
2400
floor
guest floor
F.G.L. 225 min.
1200
min.
All stairs and balustrades to be in Approx. Existing
accordance with N.C.C. - 2019 Part 3.9.1. Ground Line.
Balustrades 1000 min. above F.L. with
125mm max. openings. Approx. Proposed
Ground Line.
Selected Glass balustrade with Powder coated Nom. 200 thick Pool walls to
Handrail over. 125mm max. gap. 1000 high. engineers specification.
Rendered 200 series blockwork Timber look aluminium
walls to manufacturers specification. framed stacker doors to
manufacturers specification.
Approved Glass Pool Fence to comply with A.S.
1926. Min 1200 high max 100 mm gap. NOTE :
The Proposed Building is located in a bushfire prone area.
Building construction to be in accordance with N.C.C. part
200 series Blockwork walls with select D 3.7.4 & A.S. 3959 - 2011 (South Elevation B.A.L. 12.5 &
stone finish over to manufacturers specification North, East & West Elevations B.A.L. 19) as per private BAL
Assessor's decision. Refer to BPAD Bushfire Planning &
Design (Adrian Hansen) Bush fire Risk Assessment and
NOTE : Bushfire Risk Management Plan. The author of these drawings
All exposed Timbers to be specified on North, East and West
elevations must be in accordance with B.A.L. 19. EAST ELEVATION - B.A.L 19 accepts no responsibility whatsover for the assessment of the
B.A.L. Refer to page 102 & 103 for further construction
Scale 1 : 100
requirements.
AK B U I L D I N G D E S I G N
Dean White & Vivienne Savill Working Drawings REV D A3
DATE: 18/05/2022
© Copyright 2 Lakeway Dr. DRAWING No:
T. 07 5443 4200 E. [email protected]
A. Suite 9/50 Aerodrome Rd Maroochydore
QBCC 1060583 ABN 95 621 039 731
P.O. Box 116 Cotton Tree Qld 4558 Cooroibah 20138A / 401