  “Adamson Town Planning, specialising in providing higher order town planning advice”




It is suggested given the scale and intensity of Noosaville Medical and Professional Centre and
the location which has limited on street parking availability, the most practical solution is to
provide temporary parking elsewhere. The applicant owns 101 Eumundi Noosa Road which is
relatively close to the Noosaville Medical and Professional Centre and can be used for
temporary parking while construction is occurring, being within easy walking distance.

It is not intended to seal the temporary carpark but provide a gravel surface only. The
temporary carpark is only required until all works are completed at the Noosaville Medical and
Professional Centre. It is likely that once the carpark is sealed and operating parking will
resume at the Noosaville Medical and Professional Centre. It is not expected that a further
development approval for operational works would be required for the construction of the
temporary carpark at 101 Eumundi Noosa Road.

The applicant is committed to resolving the outstanding works required to be undertaken at
the Noosaville Medical and Professional Centre in accordance with the current approval.
Further, the applicant intends to develop the 101 & 105 Eumundi Noosa Road, generally in
accordance with the recent approval that has issued for the land with applications for
operational works currently being assessed by Council.

Under the Noosa Plan 2006, the application is to comply with the following:
   • Driveways and Carparking Code;
   • Water Sensitive Design Code;
   • Landscaping Code; and
   • Erosion and Sediment Control.

Driveways and Carparking Code
The proposed detailed design is consistent with the purpose, overall outcomes and the
relevant specific outcomes of the Driveways and Carparking Code. The parking being provided
is generally consistent with the current development approval for the site. Access is to be
obtained internally and will not adversely impact upon safety, capacity and operation of the
road network (O1). Further, the proposed driveways and crossovers across the pedestrian
pathway are suitable for their intended use.

Water Sensitive Design Code
The design of the stormwater detention basin provides for collection and treatment of
stormwater for this part of the site as well as stormwater flowing from the adjoining Telstra
Depot to the north. The proposed onsite water quality and detention basin has been designed
in accordance with the Aquaintel Stormwater Management Plan, with the planting
requirements to be in accordance with the water by design bioretention technical design
guidelines. The design of the development avoids adverse impacts on downstream
ecosystems, properties and infrastructure due to changes in flow and water quality. The
proposed development is consistent with the purpose and overall outcomes of the code.




                                                                                         3|Page
16004 – Noosaville Medical and Professional Centre Pty Ltd, October 2018
Log in to download the original file

14006 - Application for Operational Works Carpark.pdf · 527 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.