Part 9 Development codes \ 9.3 Use Codes \ 9.3.1 Low Density Housing Code
For corner lots, driveways and crossovers are located
in accordance with Council's standard drawings. Complies –
AO14.4 The driveway is existing with no changes proposed.
If in the Rural zone or Rural Residential zone, the
driveway and cross-over is located to provide minimum
safe sight distances in accordance with Austroads.
Editor's Note - An operational works application is required
for a second driveway.
Earthworks and drainage
Earthworks and Drainage AO15 Complies –
PO15 Filling other than accessways: Minor filling for the building pad has occurred
Earthworks and drainage operational works do not (a) does not extend more than the equivalent of 1.5 however the filling is all within 3.0m of the outer walls
directly, indirectly or cumulatively cause adverse metres within the urban area boundary and 3m of the dwelling as indicated on the proposal plans.
impacts external to the development site by: for rural areas, measured from the outer walls of The fill was limited to less than 500m2 and will not
(a) causing ponding of water on the site or nearby the main building; impact on the local drainage of any adjoining lot.
land; (b) is limited to a maximum of 500m2; and
(b) increasing flooding, which adversely affects the (c) does not impact on the local drainage of
safety or use of any land upstream and adjoining properties.
downstream;
(c) adversely affecting the flow of water in any
overland flow path; and
(d) adversely affecting the privacy or visual amenity
of surrounding property.
Editor's Note—Development should ensure that filling does
not impact on the amenity and usability of neighbouring
properties (including loss of privacy caused by relative level
changes) or offsite drainage.
PO16 No acceptable outcome provided N/a for a dwelling house.
Underground car parking areas are designed to drain
and function safely during a flood event and power
failure.
Editor's note—Basements should have flood immunity
above the 1%AEP defined flood event with alternative means
to mechanical pumping used to achieve such immunity.
Hazards
Print Date: 09/09/2026 Page 7
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
9-3-1LowDensityHousingCode_70_08-Sep-2026.pdfRelated documentApplication case desk ↗
About this file
- File size
- 257 KB (small file)
- File type
No other editions are linked here.