Part 9 Development codes \ 9.3 Use Codes \ 9.3.1 Low Density Housing Code
Bushfire Hazard Management AO17 Complies –
PO17 Within a bushfire hazard area where there is no The dwelling is located within a bushfire hazard area
Where located in a Bushfire Hazard Area as shown on reticulated water supply, the premises has: as per Council’s mapping. A site specific Bushfire
the Bushfire Hazard Overlay Map in Schedule 2 and (a) an accessible dam, swimming pool or water tank Report is provided. In addition, the development
not in a water service area, an adequate, reliable, available for firefighting purposes with an onsite proposes a dedicated 10,000l firefighting tank.
safely located and freely accessible water supply is water volume of not less than 5,000 litres; and Council may condition the fitting of compatible fire
provided for fire fighting purposes, which is in addition (b) a water supply outlet pipe 50 millimetres in brigade fittings.
to day to day water supply. diameter and fitted with a standard fire brigade
fitting connected to the water supply (other than
where the water supply is in a swimming pool or
dam).
Editor’s Note — Water supply capacity for firefighting
purposes is in addition to water supply capacity for
household use.
Flood Hazards AO18.1 Complies –
PO18 Where the development is located in the Flood Hazard The proposed dwelling will be situated at 3.550m
Development is designed and sited to ensure risk to Area as shown on Flood Hazard Overlay Map in AHD. The Council issue Flood Certificate indicates
people and property from flooding is avoided or Schedule 2, the finished floor level of habitable rooms the required minimum habitable floor level is 3.5m
minimised. is at least 300 millimetres above the Defined flood AHD. In addition, a site-specific Flood Report has
event (DFE). been provided by the applicant and is attached as
OR supporting information for Council. The Flood
AO18.2 Engineer has provided an assessment against the
Where the DFE has not been modelled for the area, Flood Hazard Overlay.
the finished floor level of habitable rooms is at least
500 millimetres above the highest recorded flood.
Editor's Note—The QDC mandatory provisions MP3.5 also
apply to the construction of buildings in flood hazard areas.
Landslide Hazard Area AO19.1 N/a – for a dwelling
PO19 Development, including associated access, is not
Development maintains the safety of people, property located on land identified as a landslide hazard area
and hazardous materials stored in bulk from the risk of on a Landslide Hazard Overlay Map or areas with 15%
landslide. slope or greater, as determined by a site-specific
slope-analysis
Editor's Note—A site- specific geotechnical assessment
may be used to demonstrate that although the proposed
development is shown on the Landslide Hazard Overlay as
Print Date: 09/09/2026 Page 8
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
9-3-1LowDensityHousingCode_70_08-Sep-2026.pdfRelated documentApplication case desk ↗
About this file
- File size
- 257 KB (small file)
- File type
No other editions are linked here.