App A - Acoustic Report - Minor Change - 12.08.2025

of 173

Page text read automatically using OCR, there may be inaccuracies

Sunshine Beach Surf Club                                                         Reference: #1721d1-C
Belmore Terrace, Sunshine Beach QLD 4567                                       Date: 12 November 2024
Entertainment Noise Assessment
 Prediction of Noise from Small to Medium Sized Crowds, 2011 (M.J
 Hayne, et al).

 A crowd size of 100 patrons within each outdoor specific licensed area
 was applied for this prediction. This value is aligned with the approximate
 maximum quantity supported by the study. Given the size of outdoor
 areas within the venue (Ocean/Seaside decks, function room balcony
 and outdoor lawn area), it is considered that these amounts also result in
 a generally conservative assessment.

 No adjustments for crowd orientation were applied.

 Spreadsheet calculations were conducted to predict the sound pressure
 level received at the RAPs due to patron noise. To convert sound power
 levels to sound pressure levels at the RAPs, the following formula was
 used:

                              𝐿𝑝 = 𝐿𝑤 − 20 lg 𝑟 − 11 + 𝐷𝐼

                     Where:

                             r = distance from noise source

                             DI = directivity index (assumed to be 0 dB).

 For the distance input, the shortest distance between the closest outdoor
 area (where patrons are expected to be located) to each RAP was
 calculated using a combination of QGIS and Queensland Government
 aerial imagery.

 The predicted sound pressure levels were converted to octave band
 spectra, utilising the ‘Raised’ voice spectra detailed in the AAAC
 Licensed Premises Guideline (V2).

 Patron noise levels were predicted at the CEMLs, RPLs and RAP
 measurement locations. The cumulative amplified entertainment and
 patron noise intrusive level at these locations was then calculated using
 decibel log addition. The results of the above equation were input into the
 Guideline 51 calculations (refer to Appendix B – Calculation Summaries)
 to provide an intrusive noise level due to amplified entertainment and
 patron noise.


 3.9 Instrumentation
 Table 4 below presents a list of noise survey instrumentation used for this    G51 Check Item 45 ☐

 noise assessment.




Live It Acoustics | Controlled Document v1.0                                                   Page 26

Log in to download the original (App A - Acoustic Report - Minor Change - 12.08.2025.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.