Amended plans received 14.11.25 · 51983.3225.25
Plans and drawings: the text below has words only, no drawings.
NOTES
FLAT PLASTERBOARD CEILINGS TO NOTE DESCRIPTION
UNDERSIDE OF STAIR LANDINGS - TYPICAL
AH PROPRIETARY ACCESS HATCH REFER TO
RAKING PLASTERBOARD CEILING SCHEDULE
TO UNDERSIDE OF STAIRS OVER
AW SUN AWNING
AW RISER
RISER OVER BHF PLASTERBOARD BULKHEAD
ST AW
ST EG EAVES GUTTER
VOID OVER 2800 mm C.H FTC FEATURE TIMBER CEILING FOR DETAILS
650
RISER RAKING PLASTERBOARD BHF
CEILING TO UNDERSIDE 650 4610 650 PB1 PLASTERBOARD CEILING
VRFH
PB1 PB1 OF STAIRS OVER COFFERD CEILING 150mm RECESS RB BENCH & RAIL STORAGE REFER TO
2950 mm C.H
VRFH
2400 mm C.H 2400 mm C.H SQUARE SET PLASTERBOARD TYPICAL DETAIL
1860
PB1 RB RB
CEILING EXHAUST BULKHEAD TO PERIMETER. RTH PROPRIETARY ROOF TOP HATCH REFER
HEAD HEAD 2600 mm C.H PB1 NO PAINTING REQUIRED. OWNER TO SCHEDULE
MIN 2400 HEAD CLEARANCE 2400 mm C.H
PB1 TO PROVIDE FINAL FINISHES SCR BATTEN SCREEN
HEAD
FOR STAIRS RAKE CEILING AS PB1 BHF
BHF
2600 mm C.H
BHF
REQUIRED TO ACHEIVE 2800 mm C.H CROSS BRACING ABOVE CEILING (RB) ST STAIRS
PB1
1500
3570 650 RENDERED SOFFIT VRFH
CEILING HEIGHT TO BE MAXIMISED. WEATHERTEX WEATHERGROVE XB CROSS BRACE SHOWN INDICATIVE REFER
BHF
DEPENDING ON CLEARANCES NATURAL VERANDAHS - 75MM ENGINEERS DRAWINGS FOR DETAIL
REQUIRED FOR SERVICES OVER) COFFERD CEILING 150mm RECESS
2950 mm C.H FTC SQUARE SET PLASTERBOARD
BHF
VOID
1860
RENDERED SOFFIT 2800 mm C.H RB RB 3045 mm C.H BULKHEAD TO PERIMETER.
2590 mm C.H
NO PAINTING REQUIRED. OWNER
WEATHERTEX WEATHERGROVE TO PROVIDE FINAL FINISHES
NATURAL CARPORT LEVEL - 150MM BHF BALCONY DRAINAGE ROUTED TO DP
650
XB
AW AW AW
RCP - L1 RCP - L2
1 : 100 1 : 100
RAKING PLASTERBOARD CEILING TO
UNDERSIDE OF STAIRS OVER
RISER RISER
ST
PB1 RTH AH RB
VRFH
(OVER)
2400 mm C.H PB1 RB PB1 RB PB1
RB RB (RAKING) 3200 mm C.H 2700 mm C.H
CROSS BRACING ABOVE CEILING (RB) ST CROSS BRACING ABOVE CEILING (RB)
PB1
BHF
PB1 PB1 2600 mm C.H PB1 RB
BHF
BHF
BHF
2600 mm C.H 2400 mm C.H 3000 mm C.H
BHF
PB1 EG
PB1 3000 mm C.H BEAM OVER TO PICK UP SCREENS
BHF
2400 mm C.H RENDERED SOFFIT RB
WEATHERTEX WEATHERGROVE
PB1
VRFH
2600 mm C.H 2595 mm C.H
NATURAL VERANDAHS - 75MM
PB1 RB PB1 RB RB
2400 mm C.H RB WEATHERTEX WEATHERGROVE 2400 mm C.H
SCR
VRFH
BHF
NATURAL VERANDAHS - 75MM BHF
PB1 RB
2400 mm C.H
BALCONY DRAINAGE ROUTED TO DP
RCP - L3 RCP - L4
1 : 100 1 : 100
Revision Description Date Issued By Building Class: 1 Sheet Name:
PROJECT DESCRIPTION
B2 GENERAL AMENDMENTS 28.08.2025 MD
CLIENT: B. & S. MAGANAY Climate Zone: 2
C1 DETAILED DESIGN 16.09.2025 MD
Wind: N4 (EQUIV)
RCP
11/11/2025 1:50:15 PM
D1 GENERAL AMENDMENTS 06.11.2025 MD NAME ON TITLE: SHELLEY JEANETTE MAGNAY
E1 CONTRACT DRAWINGS 11.11.25 MD ADDRESS: 3/30 HASTINGS STREET NOOSA HEADS BAL: LOW Project #: Sheet #: Rev:
Soil Class: P
Lot 3 on GTP 1154 Corrosion: C5 1070 A16 E1
© QBCC Lic no. 15143813 Noosa Shire Council Acoustic: n/a Drawn By: MD Checked By: T.J. Scale: 1 : 100
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Amended plans received 14.11.25Related documentApplication case desk ↗
About this file
- File size
- 5.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.