Amended plans received 14.11.25 · 51983.3225.25

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
    GENERAL NOTES                                                                           STRUCTURAL DESIGN                                                                            WINDOWS
    ALL DIMENSIONS IN MILLIMETRES.                                                                                                                                                       ALUMINIUM & GLAZING IN ACCORDANCE WITH
                                                                                            WHERE A STRUCTURAL ENGINEER HAS BEEN CONSULTED                                               A.S. 2047 - 2014 - WINDOWS IN BUILDINGS.
    ALL TIMBER OR STEEL FRAMED WALLS TO WET AREAS TO BE                                     - ENGINEER'S DRAWINGS AND SPECIFICATIONS TO BE                                               TO SUIT SITE DESIGN WIND LOADING.
    LINED WITH FC OR APPROVED WET AREA CLADDING, FIXED                                      STRICTLY COMPLIED WITH.
    IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.                                       RETAINING STRUCTURES                                                                         PROTECTION OF OPENABLE WINDOWS TO COMPLY WITH
                                                                                                                                                                                         NCC 2022 PART 11.3.7 AND PART 11.3.8.
    SUPSPENDED TIMBER OR STEEL FRAMED FLOORS TO HAVE WET                                    1. DO NOT BACKFILL RETAINING WALLS UNTIL 21 DAYS                                             WINDOWS TO BE PROTECTED IN BEDROOMS
    AREA FLOORING TO ALL WET AREAS, FIXED IN ACCORDANCE                                     AFTER CONCRETE HAS BEEN PLACED IN THE WALLS OF                                               WHERE WINDOW IS 2M OR MORE ABOVE THE SURFACE
    WITH MANUFACTURER'S SPECIFICATIONS.                                                     THE RETAINING STRUCTURES UNLESS NOTED                                                        BENEATH AND OTHER ROOMS WINDOWS WHERE WINDOW
                                                                                            OTHERWISE.                                                                                   IS 4M OR MORE ABOVE SURFACE BENEATH.
    THE SUB-FLOOR SPACE OF A DWELLING MUST BE VENTILATED IN                                 2. THE BACKFILL MATERIAL BEHIND THE FULL LENGTH OF
    ACCORDANCE WITH NCC 2022 H2D5 PART 6.2                                                  THE EARTH RETAINING WALLS SHALL CONSIST OF A                                                 LININGS
                                                                                            COARSE GRAINED SOIL OF HIGH PERMEABILITY (ie CLEAN
    ALL GLAZING TO COMPLY WITH NCC 2022 PART 8 AND MUST BE                                  COURSE SAND OR GRAVEL) TO MAX WIDTH OF 300MM                                                 EXTERNAL CLADDINGS AND INTERNAL LININGS
    DESIGNED FOR THE WIND LOADS SPECIFIC TO THE BUILDING.                                   FOR THE FULL RETAINING HEIGHT.                                                               TO BE FIXED AND FINISHED IN ACCORDANCE
                                                                                                                                                                                         WITH MANUFACTURER'S SPECIFICATION.
    SMOKE ALARMS MUST BE INSTALLED IN ACCORDANCE WITH NCC 2022 H3D6
    PART 9.5, BE MAINS AND INTERCONNECTED AND COMPLY WITH AS3786                            WET AREA SURFACES                                                                            TERMITES

    WATER CLOSETS (WC'S) TO HAVE A MINIMUM CLEAR WIDTH OF 900MM                             FLOOR SURFACES TO BATH & LAUNDRY SHALL BE IMPERVIOUS,                                        A TERMITE MANAGEMENT SYSTEM MUST BE INSTALLED IN
                                                                                            WITH JUNCTIONS BETWEEN WALL AND FLOOR FLASHED TO                                             ACCORDANCE WITH NCC 2022 PART 3.4 & AS3660
    DOORS TO WC'S WHICH SWING 'IN' ARE TO HAVE LIFT - OFF HINGES.                           PREVENT MOISTURE PENETRATION INTO WALLS.                                                     - TERMITE MANAGEMENT FOR A SLAB CONFORMING WITH
    PROVIDE ADEQUATE CLEARANCE AT TOP OF DOOR TO SUIT HINGES.                                                                                                                            AS2870 - RESIDENTIAL SLABS & FOOTINGS - CONSTRUCTION.
                                                                                            CERAMIC TILES OR OTHER APPROVED IMPERVIOUS MATERIAL
    ALL OTHER CONNECTIONS TO BE IN ACCORDANCE WITH A.S. A1684.2 TIMBER                      TO WALLS ABOVE SHOWERS TO 1800MM MIN ABOVE FLOOR.                                            TERMITE BARRIERS MUST BE INSTALLED IN ACCORDANCE
    FRAMING CODE.                                                                                                                                                                        WITH MANUFACTURERS RECOMMENDATIONS OR BY AN
                                                                                            SUSTAINABLE BUILDING NOTES:                                                                  ACCREDITED TECHNICIAN.
    STAIRS SHALL BE DESIGNED IN ACCORDANCE WITH NCC 2022 H5D2 PART 11.2.                    MP 4.1 - ACCEPTABLE SOLUTIONS
    RISERS (R) - 115MIN, 190 MAX
    GOINGS (G) - 240 MIN (Class 1 &10), 355 MAX;                                            1. HOME ADDITIONS TO HAVE ENERGY EFFICIENT LIGHTING                                          BUSHFIRE HAZARD AREAS
    2R+G = 550 MIN, 700 MAX                                                                 FOR A MINIMUM OF 80% OF TOTAL FIXED INTERNAL LIGHTING.
                                                                                            2. HOME ADDITIONS TO HAVE NEW AIRCONDITIONERS WITH                                           BUSHFIRE HAZARD AREAS ARE TO COMPLY WITH AS3959 &
    MAXIMUM OPENING = 125 mm
                                                                                            AN E.E.R OF 2.9 MIN.                                                                         NCC 2022 - H3 FIRE SAFETY & H3 PART 9.
    STAIR TREADS MUST HAVE A SLIP RESISTANT FINISH OR A SUITABLE NON                        3. HOME ADDITIONS TO HAVE ALL SHOWER ROSES AND TAPS
    SKID STRIP NEAR THE EDGE OF THE NOSINGS IN ACCORDANCE WITH                              SERVING LAUNDRY TUBS, KITCHEN SINKS AND BASINS WITH
    NCC 2022 H5D2 PART 11.2.                                                                A MIN 3 STAR WATER EFFICIENCY LABELLING AND STANDARDS
                                                                                            RATING. ALL TOILET CISTERNS TO HAVE A DUAL FLUSH
    ALL BALUSTRADES AND HANDRAILS TO BE 1000 MIN ABOVE FINISHED                             SYSTEM AND A MIN 4 STAR WATER EFFICIENCY LABELLING AND
    FLOOR LEVEL, 865mm MIN ABOVE STAIR NOSINGS AND HAVE NO OPENINGS                         STANDARDS RATING.
    GREATER THAN 125mm, IN ACCORDANCE WITH NCC 2022 H5D3 PART 11.3.                         OTHER
    ALL LAMINATED TIMBER BEAMS TO HAVE FULL-WIDTH BEARING AT                                VEHICLE CROSS OVERS SHALL COMPLY WITH LOCAL
    EACH END UNLESS OTHERWISE NOTED BY MANUFACTURERS                                        AUTHORITY REQUIREMENTS.
    SPECIFICATION REQUIREMENTS.
                                                                                            FIRE & ACOUSTIC SEPARATION
    CONCRETE MASONRY DESIGN TO AS 3700.
                                                                                            BUILT TO BOUNDARY WALLS & SEPARATING WALLS
    WRITTEN DIMENSIONS TO HAVE PREFERENCE OVER SCALED DIMENSIONS                            BETWEEN TWO OR MORE CLASS 1 BUILDINGS MUST BE IN ACCORDANCE
                                                                                            WITH NCC 2022 - H3D1 PART 9 FIRE SAFETY AND H4D8 PART 10.7 - SOUND INSULATION.
    ALL ASPECTS OF THIS PROJECT TO COMPLY WITH THE WORK
    HEALTH AND SAFETY ACT 2011 & AS AMENDED.

    IT IS AT THE BUILDERS DISCRETION TO POSITION BULKHEADS OR SERVICE
    PANELS UNDER FLOOR FRAMING TO ACCOMMODATE PLUMBING SERVICES.



                                                 Revision                  Description      Date       Issued By                                                     Building Class:           1 Sheet Name:
                                                                                                                   PROJECT DESCRIPTION
                                          DESIGN & VERSION
                                                                                                                   CLIENT:        B. & S. MAGANAY                    Climate Zone:             2
                                          A1                 CONCEPT PLAN                24.07.2025   MD
                                                                                                                                                                     Wind:             N4 (EQUIV)
                                                                                                                                                                                                                            GENERAL NOTES




                                                                                                                                                                                                                                                              11/11/2025 1:50:17 PM
                                          B2                 GENERAL AMENDMENTS          28.08.2025   MD           NAME ON TITLE: SHELLEY JEANETTE MAGNAY
                                          C1                 DETAILED DESIGN             16.09.2025   MD           ADDRESS:       3/30 HASTINGS STREET NOOSA HEADS   BAL:                   LOW Project #:                  Sheet #:             Rev:
                                          D1                 GENERAL AMENDMENTS          06.11.2025   MD                                                             Soil Class:               P
                                          E1                 CONTRACT DRAWINGS           11.11.25     MD
                                                                                                                   Lot 3 on GTP 1154                                 Corrosion:               C5                  1070                 A17              E1
©   QBCC Lic no. 15143813                                                                                          Noosa Shire Council                               Acoustic:                n/a   Drawn By:   MD Checked By:     T.J. Scale:      1 : 100

Used in these records

About this file

File size
5.5 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Amended plans received 14.11.25.pdf · 5.5 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.