               51.    Each individual water connection to the water reticulation system shall extend to the property
                      boundary and be metered. All fees for the supply of water meters shall be paid to Unitywater.
               52.    All water meters must be located outside the property boundary and in an easily assessable
                      location to facilitate unhindered reading by Unitywater and/or Unitywater’s contracted water
                      meter readers, and not behind fences or locked gates. In this regard approval of the water
                      meter configuration and location must be obtained from Unitywater prior to lodgement and
                      approval of hydraulic drawings.
               53.    For Multiple Uses (including Building Format Plans, Group Title Plans, etc) the development
                      shall be served by:
                      a.      A single Body Corporate water meter to measure the total water consumption
                              (including fire hose reels, but excluding fire hydrants and fire sprinkler systems), and
                      b.      Individual water meters to each tenement capable of being separately rated, and
                      c.      A fire service (fully testable single detector check with metered bypass), where
                              applicable, for flows to fire hydrants and fire sprinkler systems (excluding fire hose
                              reels).
               54.    Fire hydrants are to be provided throughout the development in accordance with Council
                      Engineering Design Standards and in accordance with Queensland Fire Service Standards.
                      The applicant is advised that this development may require the provision of fire hydrants and
                      a booster pump in accordance with the Building Code of Australia, and consultation may also
                      be needed with Queensland Fire Services to ensure suitable fire fighting infrastructure is
                      provided. To this end any necessary fire hydrants shall be clearly shown on the plans
                      submitted for both Operational Works and Building Works approval and if a booster pump is
                      deemed necessary, the plans shall indicate where the fire truck is to be accommodated in
                      order to provide boosting to the water supply.
               Earthworks
               55.    Filling works required on site shall be carried out in accordance with Council’s Planning
                      Scheme Policy PSP5 – Engineering Design Standards, so as not to cause the additional
                      ponding of water on any adjoining lands or the blockage of, or interference with, any natural
                      watercourses. Detailed site surveys indicating natural surface levels and contours of the
                      adjoining properties must be provided with the application for a Development Permit for
                      Operational Works for Filling and Drainage.
                      This may require the design and construction of drainage pipes and/or an overland flow-path
                      within the development site that caters for drainage from the adjoining sites for a design
                      storm with an Average Recurrence Interval of 1 in 100 years. A private easement for the
                      Drainage of Water encompassing the drainage pipes or overland flow-path will also be
                      required. In this regard a Development Permit for Operational Works shall be obtained.
                      Should evidence be provided to Council indicating that no additional ponding of stormwater
                      will occur on the adjoining properties the requirement for the drainage pipes, overland flow-
                      path and easement shall not apply.
               56.    Earthworks carried out on site shall not affect the structural integrity of any of the existing
                      fences or structures that border the development site. Fences that are affected shall be
                      replaced prior to the Building Certifier issuing the Certificate of Classification. In this regard
                      any fences to be replaced shall be clearly shown on the plans submitted for Operational
                      Works approval.
               57.    Any filling works shall be retained with constructed walls that are designed and located to
                      minimise impacts on the vegetated buffers areas indicated on the approved plan of
                      development.




                                                                                                         Page 8 of 17
Document Set ID: 22829529
Version: 4, Version Date: 29/02/2024
Log in to download the original file

Decision Notice - Minor Change - 132007 738 05 [As published].pdf · 214 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.