Roof Water & Stormwater Drainage
8.    Roof runoff from any new dwelling shall be directed to a rainwater storage system or tank that
      is installed to ensure water from the rainwater storage system or tank is used for external uses
      (such as watering gardens, irrigation, ornamental ponds, water features, topping-up swimming
      pools, outdoor cleaning, etc) and for internal (ground floor) use in washing machine cold taps
      and toilet cisterns. All rainwater tanks are to be designed and installed in accordance with the
      Queensland Development Code (QDC) current at the time of building approval, and shall be
      part of the plumbing application for approval. The location and capacity of the tanks shall be
      clearly shown on the plans submitted for Building approval and any overflow shall be
      discharged in a manner that will not cause scour and will not cause ponding on neighbouring
      properties.
9.    All stormwater drainage (including roof water overflow from the rainwater storage system)
      shall be collected and discharged so there is no net increase in stormwater runoff from the
      site.
10.   All site stormwater drainage shall be by means of a gravity system.
Earthworks
11.   As parts of the site are proposed to be filled to raise the effluent disposal area above Q100
      flood level, the applicant must undertake filling in a manner that will not increase the flood
      levels in the vicinity or cause additional ponding/flooding on neighbouring properties.
12.   Filling works are only permitted for the purpose of constructing the effluent disposal area
      above the Q100 flood level. The total area of fill on site is not permitted to increase as a result
      of filling for the expansion of the effluent disposal area.
13.   Filling works required on site shall be carried out in accordance with Council’s Planning
      Scheme Policy PSP5 – Engineering Design Standards, so as not to cause the additional
      ponding of water on any adjoining lands or the blockage of, or interference with, any natural
      watercourses.
14.   Filling in order to expand the footprint of the building pad is not permitted.
Erosion and Sediment Control
15.   Any person acting on this permit shall prevent erosion and sediment export from leaving the
      site. Site control measures such as silt fencing, controlled gravel access to the site and
      controlled disposal of waste, will be necessary.
      In this regard, plans detailing the methods of controlling erosion and sediment in accordance
      with the Healthy Waterways document and fact sheet series titled Controlling Stormwater
      Pollution on your Building Site dated 2006 are required to be submitted with the application for
      a Building Works Permit.
Contributions Towards Council Infrastructure
16.   Monetary contributions shall be paid to Sunshine Coast Regional Council towards the cost of
      providing and/or upgrading various infrastructure at the rates applicable at the time of
      payment. An estimate only of the contribution amounts under the current Council policies and
      requirements is outlined in the table below:

       Contribution Required For:                                                       Amount:
       PSP12 – Public Open Space Contributions (Park)                                   $543.00
       TOTAL Contribution Amount =                                                      $543.00
       Please note that these amounts are all subject to variations in the Consumer Price Index, All
       Groups Brisbane from December 2008 until the date of payment.


                                                                                       Page 3 of 12

Used in these records

About this file

File size
312 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Decision Notice - 010.2009.00000152.001 [As Published].pdf · 312 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.