Council archive · source document
20080490 - Decision Notice [As Published] · 112008.490
Project Job No. 90775 Slab as per Report Knock Out. ——~ Block 1800 (Max) NOTE: Py Conrete is to be vibrated Trodded into block cavity. Reinforcement Bars (Refer Table) aa ey =] 4% 3 Barl11 Trench Mesh Top and Bottom : ‘ 500Min. : ' Embedment 600 t ! aes Starter Bar ke 0 > Wall Height Reinforcement 0 to 600 mm a N12's @ 1000 mm Ctrs. Vertical N12's' @.400 mm Ctrs. 600 fo (300 mm Vertical and Horizontal N16's @ 400 mm Ctrs. 7200 to 1800 mm Vertical and Horizontal tes: + Excavation shall be taken into natural material with min. allowabie bearing capacity of 150 KPa. - All excavations shall be finished cleaned & horizontal. + The builder shail place retaining wall toe into specified founding material. + Retaining wall is not to be back for a min. af 1 week after concrete core filling. ~ All cores to be infilled with concrete grout - 20 Mpa minimum. Concrete is to be vibrated/rodded into brick cavity. - Surface is to be clean of dirt, oil, wax or other loose matter. All holes and surface defects to be made good. Joints in blockwork / brickwork to De flush. - Apply full brush coal of neofiex as supplied by chemical industries or other equal product to all corners, around penetrations ete. and allowed to dry. + Apply full brush coat of neotlex to all vertical and horizonta! walt direct from the can as recommended by the manufacturer. + Protect the coated wall surface with ‘protect board" or simitar to prevent damage to the membrane during backfilling. Page 3 of 5 Edge Beam Footing Connection New Section of Footing 200 400 | oe eT) Existing é Footing ae wT \ V 2xN12 Bars (Top & Bottom) dowelled Fabricated Cage into existing footings Slab Edge Connection Ableflex or Existing Similar Slab cate nanee eee ssteeeee sees e ° Footings and Slab . as per Page 5 re Existing oa Footings Slab Edge Connection Dowell Bars Y12 @ 300 Ctrs. le 150 —>| | EXISTING SLAB y. NEW SLAB h100 mm 150mm 300 Edge Beam Existing Foofag— 9 Reinforcement Design Company Builder SOILTEST AUSTRALIA ENGINEERING SERVICES PTY LTD SIA Diane Jones & Don Cielland Suite 1, 848 Boundary Rd, Richlands, Qld, 4077 ACN 109 233 123 Fax (07) 33759299 Ph.1300 731523 ALLIANCE 575 Black Mountain Road, Cooroy Qld 4563 Builders Client N/A Client Order Number. N/A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20080490 - Decision Notice [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.