For refrigeration equipment, Section 440V of the Act states that an occupier of a premises (at or
for which there is refrigeration equipment) or an owner of refrigeration equipment must not use,
or permit the use of, equipment on any day:
a) Before 7am, if it makes a noise of more than 3dBA above the background level; or
b) From 7am to lOpm, if it makes a noise of more than SdBA above the background
level; or
c) After lOpm, if it makes a noise of more than 3dBA above the background level.
The above limits apply to air conditioning equipment and refrigeration equipment that would be
installed within the proposed commercial development site. We note that there is possibility that a
supermarket could be developed at the site, which could result in refrigeration plant operating
continuously for 24-hours. Therefore noise emission limits should be determined for day, evening
and night time periods.
The Act does not specify the noise measurement parameter which is represented by the default
noise standard limits. When measuring continuous noise from mechanical plant, the parameter
which is usually used is the LAeq noise level.
The LA90 noise levels associated with the existing acoustic environment are presented in Table 1 and
Table 2. From these levels, the corresponding limits for mechanical and refrigeration plant can be
derived for surrounding residences as presented in Table 6.
Table 6: Criteria for mechanical plant noise emissions at residences
Noise Emission Limits
,
Noise Criteria
DaV Evening Night
.
6pm) (6pm -lOpm) (10pm -7am)
^
(7am -
Acoustic Quality Objectives (EPP(Noise))
Outdoors: LAeq, adJ, 1hr SOdBA SOdBA -
410,adj, 1hr SSdBA SSdBA -
LA01, adJ, lhr 6SdBA 6SdBA -
Resulting strictest component limits, LAeq, adj, lhr SOdBA SOdBA -
Background Creep Considerations (EPP(Noise))
For noise that is continuous:
Measured LA90 43dBA 40dBA 40dBA
Allowable exceedence of existing LA90 value OdBA OdBA OdBA
Resulting component noise limits LA90 43dBA 40dBA 40dBA
For noise that varies over time:
Measured LA90 43dBA 40dBA 40dBA
Allowable exceedence of existing LA90 value SdBA SdBA SdBA
Resulting component noise limits LAeq, adj 48dBA 4SdBA 4SdBA
Default Noise Standard (Act)
Measured 490 43dBA 40dBA 40dBA
@ Renzo Tonin Ron Rumble Proposed Shopping Centre, Rufous Street, Peregian
Noise Impact Assessment
Q9554-01F02 (Rev 3) Peregian Shopping Centre.doc Multi Span Australia Group pty Ltd
5August 2013 Page 15
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Response to Information Request 5-7 Rufous Street Peregian Beach - Attachment D MCU13/0092Related documentApplication case desk ↗
About this file
- File size
- 23.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.