         For refrigeration equipment, Section 440V of the Act states that an occupier of a premises (at or

         for which there is refrigeration equipment) or an owner of refrigeration equipment must not use,

         or   permit the use of, equipment on any day:


                    a)        Before 7am, if it makes a noise of more than 3dBA above the background level; or


                    b)        From 7am to      lOpm, if it makes a noise of more than SdBA above the background

                              level; or

                    c)        After lOpm, if it makes a noise of more than 3dBA above the background level.



         The above limits apply to air conditioning equipment and                 refrigeration equipment that would be
         installed within the proposed commercial development site. We note that there is possibility that a

         supermarket could be developed at the site, which could result in refrigeration plant operating
         continuously for 24-hours. Therefore noise emission limits should be determined for day, evening
         and night time periods.



         The Act does not specify the noise measurement parameter which is represented                          by the default
         noise standard limits. When                measuring continuous noise from mechanical plant, the parameter
         which is usually used is the LAeq noise level.




    The LA90 noise levels associated with the existing acoustic environment are presented in Table 1 and

        Table 2. From these levels, the corresponding limits for mechanical and refrigeration plant can be

         derived for surrounding residences as presented in Table 6.

                            Table 6: Criteria for mechanical plant noise emissions at residences

                                                                                  Noise Emission Limits
                  ,



                                   Noise Criteria
                                                                         DaV      Evening      Night
              .

                                                                           6pm) (6pm -lOpm) (10pm -7am)
          ^



                                                                     (7am   -




      Acoustic Quality Objectives (EPP(Noise))

      Outdoors: LAeq, adJ, 1hr                                          SOdBA              SOdBA                  -




                      410,adj, 1hr                                      SSdBA              SSdBA                  -




                      LA01, adJ, lhr                                    6SdBA              6SdBA                  -




      Resulting strictest component limits, LAeq, adj, lhr              SOdBA              SOdBA                  -




      Background Creep Considerations (EPP(Noise))

                  For noise that is continuous:

                  Measured LA90                                         43dBA              40dBA              40dBA

                  Allowable exceedence of existing LA90 value            OdBA               OdBA               OdBA


                  Resulting component noise limits LA90                 43dBA              40dBA              40dBA

                  For noise that varies over time:

                  Measured LA90                                         43dBA              40dBA              40dBA

                  Allowable exceedence of existing LA90 value            SdBA               SdBA               SdBA


                  Resulting component noise limits LAeq, adj            48dBA             4SdBA               4SdBA

      Default Noise Standard (Act)

      Measured 490                                                      43dBA              40dBA              40dBA



@ Renzo Tonin Ron Rumble                                                        Proposed Shopping Centre, Rufous Street, Peregian
                                                                                                        Noise Impact Assessment

Q9554-01F02 (Rev 3) Peregian Shopping Centre.doc                                                Multi Span Australia Group pty Ltd

5August 2013                                                                                                             Page 15

Used in these records

About this file

File size
23.1 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Response to Information Request 5-7 Rufous Street Peregian Beach - Attachment D MCU13_0092.pdf · 23.1 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.